Figure 13. 900 EX Operating Limits
Voltage refers to the limit on either channel, not the
output.
4.3.1 INDEPENDENT CONFIGURATION
When the 900 EX is powered up, it is always in the Independent Configuration.
Output A and Output B operate completely independently, allowing Load A
and Load B to be controlled separately. Each load is connected from the positive
terminal to the negative terminal of the appropriate output.
The name Independent is used due to the separate set-up procedures required for
each output and the independent control that each DC Converter has over its own
output. A single load may be connected in Independent Configuration (i.e., either
Load A or Load B) with no change in functionality. A load connected to an 900 EX
in the Independent Configuration is illustrated in Figure 14.