background image

7

10  Fault codes

Status / Error message

Possible cause 

Correction 

A09

 

Fault, cabin temperature sensor 

Cabin temperature sensor defective,  break/short-circuit in electrical circuit,  cabin temperature sensor not connec-  ted. 

Please contact your authorised Webasto Marine  dealer.

 

A10

 

Malfunction, water temperature sen- sor 

Water temperature sensor defective or  break/short-circuit in electrical circuit. 

BA11

 

Required cold water temperature not  yet reached

Air handler is only switched on when  the required cold water temperature is  reached.

No action required. The air handler starts up auto- matically.

INIT

 

Initialisation procedure or system blo- cked.

Electrical wiring defective. 

Power circuit interruption/short circuit. 

Please contact your authorised Webasto Marine  dealer.

 

n/a

 

No pc-board output

Fuse faulty or break/short-circuit in this  electrical circuit. 

Pc-board damaged by high voltage  (RT1 blown) 

n/a

 

No or insufficient cooling or heating  capacity.

Poor air or water flow. 

Secure adequate air or water flow 

Chiller unit not switched on. 

Switch on the chiller unit and check whether the  cold water circuit reaches the required tempera- ture for cooling or heating.

n/a

 

Incorrect cabin/ambient temperature  or water temperature displayed.

Temperature sensor positioned incor- rectly, subject to interference or display  values falsified. 

Check whether the temperature sensor is subject  to direct fault sources such as direct sunlight or  devices radiating heat.

Please contact your authorised Webasto Marine  dealer. 

Summary of Contents for BlueCool A-Series

Page 1: ...ad this operating instruction and the supplementary sheet Im portant Information on Operating and Instal lation Instructions X X Keep these operating instructions ready to hand X X Hand these operatin...

Page 2: ...The air conditioning systems must ALWAYS be switched off during refuelling or while in a petrol station area 3 Description The BlueCool MyTouch is the standard control element for the BlueCool A Serie...

Page 3: ...matic mode 6 Settings The symbols on the Home screen provide infor mation on the system status The symbols are explained in the table below Symbol Meaning 1 On Off 2 Temperature 3 Fan 4 Settings 6 Not...

Page 4: ...the room temperature measured by the cabin temperature sensor Note The system only cools under the following conditions cabin tem perature 15 C Setpoint temper ature cabin temperature The system only...

Page 5: ...to reduce the time interval or tap to increase the time interval The symbol marks the current selection X X Tap on the required time to set the time in terval X X Tap the Previous symbol to go to the...

Page 6: ...ight Cabin temperature dark Shows the current cabin temperature at low brightness levels in areas with little am bient light Display off No display in standby mode Operation indicator An illuminated d...

Page 7: ...al wiring defective Power circuit interruption short circuit Please contact your authorised Webasto Marine dealer n a No pc board output Fuse faulty or break short circuit in this electrical circuit P...

Page 8: ...sions the German language is binding The telephone number of each country can be found in the Webasto service centre leaflet or the website of the respective Webasto representative of your country Web...

Reviews: