Troubleshooting – BlueCool Truck Electrical System
www.webasto.us
19
Webasto Product N.A., Inc.
™
Checking 12 volt constant positive from batteries (20 amp. fuse) to system control relay X10
Figure 20. 12 volt constant positive from batteries (20 amp. fuse) to system control relay Pin-87 and ground on Pin-85
(DC Voltage)
Checking switched 12 volt output from relay X10
Figure 21. Switched 12 volt output from Pin-30 of relay X10 to condenser fan Pin-1 of connector X9 and Pin-86 of
inverter switching relay X11 (ground on Pin-85 of relay X10 and X11)
V DC
V
V
Volts DC
_
+
ON
POWER
OFF
To Inverter
ON/OFF Circuit
X10
X11
Blue 12GA - 12V Switched Output to Condensor Fan (X9)
Brown 14GA - Ground to Battery Negative Post
Purple 16GA - 12V Input from Control Module (X1),
Pressure Sensor (X6) and Ambient Thermostat (X7)
Red 12GA - Constant Power Positive (Fused 20 amp.)
Not Used
Viewed from wire insertion side
LEGEND
87a
87
30
85
86
30
85
86
87
87a
X10
V DC
V
V
Volts DC
_
+
ON
POWER
OFF
X10
X11
Blue 12GA - 12V Switched Output to Condensor Fan (X9)
and Inverter Switching Relay (X11)
Brown 14GA - Ground to Battery Negative Post
Purple 16GA - 12V Input from Control Module (X1),
Pressure Sensor (X6) and Ambient Thermostat (X7)
Red 12GA - Constant Power Positive (Fused 20 amp.)
Not Used
Viewed from wire insertion side
LEGEND
87a
87
30
85
86
30
85
86
87
87a
To Inverter
ON/OFF Circuit
X10
OFF
ON
ACC
Key Switch
Position
> 30 min.