3 Functional Description
Thermo 90
302
3.4
Switch-off
When switching the heater off, the operation indicator
on the timer/switch extinguishes. Combustion ends and
run-down is initiated. Circulation pump and combustion air
fan, however, continue operation to cool down the heater
(run-down) and are automatically deactivated after about
90 seconds. A reactivation of the heater during run-down
is permitted.
Room temperature control by means of the vehicle's own
heating blower may be provided in addition to employing
a room thermostat.
3.5
Functions of the Heater in TRS
Vehicles
The heater is started using the switch. A TRS condition
(forced deactivation) will be released after
–
the vehicle engine is turned off
–
a conveyor facility is started
with the short run-down terminating after 20 seconds.
Then the control unit is in the "error lockout" mode. Prior
to reactivation the On/Off switch must be set to "Off".
The isolation switch (emergency off switch) must only be
operated in case of emergency, as the heater is switched
off without run-down (overheating possible).
Fig. 301 Functional Sequence
Functional Sequence for Thermo 90
Switch-on
Configuration Check
Preheating 40 sec. (cycled)
Dosing Pump Priming 5 - 7 sec. (1)
Dosing Pump / Part Load (1/4)
Flame Sensor Take-over
Stabilisation Time
Full Load
Vehicle Blower »On«
Control Range
Control Idle
Flame Sensor »cold« (0)
Run-down completed
Preheating 15 – 20 sec. (cycled)
Dosing Pump Priming 5 – 7 sec. (1)
Dosing Pump / Part Load (1/4)
Flame Sensor Take-over
Stabilisation Time
Coolant Temperature down
Full Load
Switch-off (run-down)
Flame Sensor "cold" (0)
Run-down completed
A
Glow Plug
B
Dosing Pump
C
Combustion Air Fan
D
Flame Sensor
E
Operation Indicator Light
F
Circulation Pump
A
B
C
D
E
F
G
1
0
1
0
0
0
0
0
0
1
1
1
1
1
1
/
4
1
/
2
1
/
4
*
30
80
90
75
70
°
C
23
22
21
20
19
17
16
14
13
11
10
18
15
12
9
8
6
4
3
1
2
5
7
Sicherheitszeit
❏
*
In case of a no-flame-
condition automatic restart
is initiated (20 sec. cycled
preheating, 90 sec. safety
time)
o
Possible codeable control
temperatures, see table
below
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Summary of Contents for Thermo 90
Page 9: ...1 Introduction 104 Page free for notes ...
Page 13: ...2 General Description Thermo 90 204 Page free for notes ...
Page 18: ...Thermo 90 3 Functional Description 305 Page free for notes ...
Page 20: ...4 Technical Data Thermo 90 402 Page free for notes ...
Page 26: ...6 Functional Tests Thermo 90 602 Page free for notes ...
Page 41: ...Thermo 90 8 Servicing 809 Page free for notes ...
Page 53: ...10 Packaging Storage and Shipping Thermo 90 1002 Page free for notes ...