Thermo 90
5 Troubleshooting
501
5
Troubleshooting
5.1
General
This section describes troubleshooting procedures for the
Water Heater Thermo 90 and Thermo 90 S.
CAUTION
Troubleshooting requires profound knowledge about
structure and theory of operation of heater components
and may only be performed by skilled personnel.
In cases of doubt refer to Sections 2 or 3 for functional
interrelations.
CAUTION
Troubleshooting is normally limited to the isolation of
defective components.
The following defects are not included in the trouble
shooting procedures. Before troubleshooting, check for
and eliminate these defects:
•
corrosion on connector
•
loose contact on connector
•
wrong crimping on connector
•
corrosion on electrical wiring and fuses
•
corrosion on battery terminals
After any correction of a failure a functional test has to be
performed in the vehicle; before switch the heater off and
on again.
5.2
General Failure Symptoms
The following table (Fig. 501) lists possible, general failure
symptoms.
Fig. 501 General Failure Symptoms
NOTE
In many cases the probable cause of failure may be the
burner. Perform a visual inspection according to 5.4.
Failure Symptom
Failure Symptom
Remedy
Heater switches
off automatically
No combustion after start or repeat
start
Control unit goes to error lock-out.
Switch heater off and on again
Flame extinguishes during operation
If a no-heating condition persists
contact Webasto service agent
Heater overheats due to lack/loss of
coolant
Replenish coolant.
After cool-down of unit, push button of
temperature limiter before reactivation
or replace temperature limiter
Low voltage condition for more than
20 seconds
Check fuses, connections, and charge
of battery.
Switch-off caused by temperature
limiter
After cool-down of unit, push button
of temperature limiter before
reactivation or replace temperature
limiter.
Summary of Contents for Thermo 90
Page 9: ...1 Introduction 104 Page free for notes ...
Page 13: ...2 General Description Thermo 90 204 Page free for notes ...
Page 18: ...Thermo 90 3 Functional Description 305 Page free for notes ...
Page 20: ...4 Technical Data Thermo 90 402 Page free for notes ...
Page 26: ...6 Functional Tests Thermo 90 602 Page free for notes ...
Page 41: ...Thermo 90 8 Servicing 809 Page free for notes ...
Page 53: ...10 Packaging Storage and Shipping Thermo 90 1002 Page free for notes ...