9 Repair
Thermo 90
902
9.2
Disassembly and Assembly
9.2.1 Electrical Connections (Fig. 901)
9.2.1.1 Disconnecting Electrical Connections
(Connection X1)
NOTE
All electrical connections are joined in the connector.
Prior to removal of a component, the relevant electrical
connections first have to be disconnected.
On heater Thermo 90 S with flanged combustion air fan
connector X1 on heater and connection X12 on control
unit must be disconnected and reconnected after making
electrical connections.
1. Remove top cover from heater.
2. Using removal tool (hook end) withdraw lock wedge
from connector.
3. Using removal tool (screw driver end) press down
relevant locking tab and keeping tab depressed
withdraw cables from connector.
9.2.1.2 Making Electrical Connections
1. Slide cable into relevant contact pocket until locked.
2. Using removal tool (screw driver end) insert lock
wedge in connector and press in until locked.
3. Fit top cover.
Fig. 901 Electrical Connections
Thermo 90
Lock Wedge
Locking Tab
(12 off)
Top Cover
Removal Tool
Supplier of Removal Tool
(Order No. DT RT1)
Compagnie Deutsch GmbH
Fraunhoferstr. 11b
82152 Martinsried
Tel. 0 89 / 8 99 15 70
Fax 0 89 / 8 57 46 84
NOTE
One of the newer models Thermo 90 shown. Older
models have the cable of the temperature limiter located
on the side.
Heater Thermo 90 S may have the control unit located on
the combustion air fan.
Summary of Contents for Thermo 90
Page 9: ...1 Introduction 104 Page free for notes ...
Page 13: ...2 General Description Thermo 90 204 Page free for notes ...
Page 18: ...Thermo 90 3 Functional Description 305 Page free for notes ...
Page 20: ...4 Technical Data Thermo 90 402 Page free for notes ...
Page 26: ...6 Functional Tests Thermo 90 602 Page free for notes ...
Page 41: ...Thermo 90 8 Servicing 809 Page free for notes ...
Page 53: ...10 Packaging Storage and Shipping Thermo 90 1002 Page free for notes ...