14 | Basic Troubleshooting
42
14.2
General Failure Symptoms
The following table lists possible failure symptoms.
Heater switches
off automatically
(fault lockout)
No combustion after start or auto-
matic repeat start
Switch off heater momentarily and switch on again
Flame extinguishes during opera-
tion
Check coolant lines for obstructions, closed
valves, and kinks.
Check coolant level, bleed coolant circuit if ne-
cessary. Allow heater to cool down. Check for
failure codes and repeat as necessary.
Heater overheats
Charge/replace batteries
Switch off heater momentarily and switch on
again
Heater expels
black smoke from
the exhaust
Combustion air and/or exhaust tube
blocked
Check combustion air intake and/or exhaust tube