R 125 E
1998 / 1999
GENERAL DIRECTIONS FOR USE
Below you will find the main steps to be taken for
using your heater. For more details, please refer to
the MANUAL (pages 67 ff.).
•
As a fire precaution, the tank must be filled
either when the heater has been switched off or
in another room than the room where the heater
is installed.
•
Always ensure that the tank is closed properly
after filling it at a safe distance from all sources
of heat and open flames (see chapter B).
•
Store all fuel containers with their original caps
and seals in a cool and dark place.
•
Fuel ages. Use new fuel at the start of every
heating season.
•
The use of Qlima Premium Quality Fuels as a
heating fuel assures you that you have a good
quality fuel.
•
Before changing brands and/or types of fuel
make sure that the mobile heater first completely
empties all of the remaining fuel inside the
heater.
MAIN COMPONENTS
OFF - button
Knurled wick
adjustment knob
Ignition button
Combustion
chamber
Combustion
chamber handle
Fuel indicator
Grill
Lid for removable
tank
Removable tank
Fuel gauge
removable tank
Ignition coil
Battery holder
Handle
Cabinet
A
B
C
4
E
F
G
H
I
J
K
L
Remove all packaging materials
(refer to Section A, Fig. A).
Fill the removable tank
I
and wait 30 minutes before you
ignite the heater
(refer to Section B, Fig. I).
Insert the batteries into the battery holder
L
(refer to Section A, Fig. G).
Check whether the combustion chamber
D
is fully upright
(refer to Section A, Fig. F).
Ignite the heater by turning the knurled wick adjustment
knob
B
as far to the right as possible and then gently push the
ignition button
C
(refer to Section C, Fig. K and L).
After igniting the heater it will take 10 to 15 minutes before
you can check if the heater burns well
(refer to Section D).
Switch off the heater
(refer to Section E).
1
2
3
4
5
6
7
4
65
Summary of Contents for R172TC
Page 3: ......
Page 156: ...34 1998 1999 R 125 E K GARANCIJSKI POGOJI y 156 ...
Page 160: ...FQ 7 0 0 5 cm 3 7 ...
Page 161: ...A B C D G E J F H I K L ...