- Put the soil compactor out of operation as described in paragraph
2.7.
- Lift the soil compactor by means of a crane as described in
paragraph 2.2.1.
- Put the damper plate beneath the machine.
Caution!
Do not enter the zone under the suspended load. - Risk of
injury!
- Attach the Vulkollan plate (6a/1), together with the holder (6/2),
the screws, lock washers and the nut (6/3), to the front of the base
plate (6/4) as shown.
- Attach the Vulkollan plate (6a/1), together with the holder (6a/3),
the screws, nuts and the lock washers (6a/2) to the back of the
base plate (6/4).
Important!
Check to ensure that the Vulkollan plate is correctly fitted
beneath the base plate.
Danger!
Do not enter the zone under the suspended load!
Figure 6
Figure 6a
2.4.4 Fitting/Detaching the Extension Plates
- Undo three each fastening screws (6b/2) and remove the
extension plates.
- Put the extension plates (6b/1) against both sides of the base
plate and fix them by means of three each fastening screws (6b/
2).
Firmly tighten the screws!
1
3
4
2
3
1
2
Figure 6b
1
2.4.3 Fitting the Damper Plate
2