Technical data
3.2
Operating conditions
The permissible operating temperature range for the spreader lies between -20° C and +55° C.
Reliable operation cannot be guaranteed outside of this range.
Underwater operation
The spreader can also be used under water. Do not exceed the maximum submersion
depth of 40 metres with this. At this depth the water pressure still has no influence on the
hydraulic pressure in the equipment and the hoses.
NOTE !
After underwater use in saltwater, the equipment must be completely
disassembled and cleaned. With fresh water complete cleaning is
sufficient.
3.3
Type plate
On all spreder devices, the type plate is located on the body. It shows the serial number,
production date, nominal pressure and device designation.