127
V2.0/02.11
Description of the memory functions
ENGLISH
13. Description of the memory functions
Configuring the measured value memory
DATA FORMAT ACT
During the recording interval
(for example, 50 ms), the current meas-
urement value (ACT) only will be written
to the measured value memory.
MIN-MAX
During the recording interval
(for example, 50 ms) one MIN and one
MAX value will be written to the meas-
ured value memory.
REC CONFIG
2 000 PTS
The selected recording time is auto-
matically divided into a fixed number of
recording intervals per channel.
Example:
10 min recording time = 600 s
Duration of recording interval =
600 s ÷ 2.000 = 300 ms
REC RATE
Definition of an individual recording
interval (for example, 5 ms).
Based on the settings (DATA FORMAT/
REC RATE), the measuring instrument
examines if the selected recording time
must be extended.
Example:
Recording time 100 h/conflict
recording time
FAST MODE
ACT measured values only are saved
at a fixed recording interval of 0.5 ms
via IN1. All other inputs (INx) are not in
function.
Summary of Contents for HPM540
Page 1: ......
Page 2: ......
Page 4: ...4 V2 0 02 11 Vorwort...
Page 28: ...28 V2 0 02 11 Ger teeinstellungen SET 6 Ger teeinstellungen SET SET dr cken 2 s...
Page 29: ...29 V2 0 02 11 Ger teeinstellungen SET DEUTSCH...
Page 38: ...38 V2 0 02 11 Das Men REC 8 Das Men REC...
Page 39: ...39 V2 0 02 11 Das Men REC DEUTSCH...
Page 47: ...47 V2 0 02 11 Messwertspeicherung DEUTSCH...
Page 50: ...50 V2 0 02 11 Messwertspeicherung...
Page 53: ...53 V2 0 02 11 Messwertspeicherung DEUTSCH...
Page 68: ...68 V2 0 02 11 Beschreibung der Speicherfunktionen...
Page 70: ...70 V2 0 02 11 Foreword...
Page 94: ...94 V2 0 02 11 Device settings SET 6 Device settings SET Press and hold SET 2 s...
Page 95: ...95 V2 0 02 11 Device settings SET ENGLISH...
Page 104: ...104 V2 0 02 11 The REC menu 8 The REC menu...
Page 105: ...105 V2 0 02 11 The REC menu ENGLISH...
Page 113: ...113 V2 0 02 11 Recording measured values ENGLISH...
Page 116: ...116 V2 0 02 11 Recording measured values...
Page 119: ...119 V2 0 02 11 Recording measured values ENGLISH...
Page 136: ...136 V2 0 02 11 Pr face...
Page 160: ...160 V2 0 02 11 R glages de l appareil SET 6 R glages de l appareil SET SET 2 s...
Page 161: ...161 V2 0 02 11 R glages de l appareil SET FRANCAIS...
Page 170: ...170 V2 0 02 11 Le menu REC 8 Le menu REC...
Page 171: ...171 V2 0 02 11 Le menu REC FRANCAIS...
Page 179: ...179 V2 0 02 11 Enregistrement des valeurs de mesure FRANCAIS...
Page 182: ...182 V2 0 02 11 Enregistrement des valeurs de mesure...
Page 185: ...185 V2 0 02 11 Enregistrement des valeurs de mesure FRANCAIS...
Page 202: ...202 V2 0 02 11 Premessa...
Page 226: ...226 V2 0 02 11 Impostazioni dello strumento SET 6 Impostazioni dello strumento SET SET 2 s...
Page 227: ...227 V2 0 02 11 Impostazioni dello strumento SET ITALIANO...
Page 236: ...236 V2 0 02 11 Il menu REC 8 Il menu REC...
Page 237: ...237 V2 0 02 11 Il menu REC ITALIANO...
Page 245: ...245 V2 0 02 11 Salvataggio dei valori misurati ITALIANO...
Page 248: ...248 V2 0 02 11 Salvataggio dei valori misurati...
Page 251: ...251 V2 0 02 11 Salvataggio dei valori misurati ITALIANO...
Page 268: ...268 V2 0 02 11 Pr logo...
Page 292: ...292 V2 0 02 11 Ajustes del aparato SET 6 Ajustes del aparato SET Pulsar SET 2 s...
Page 293: ...293 V2 0 02 11 Ajustes del aparato SET ESPA OL...
Page 302: ...302 V2 0 02 11 El men REC 8 El men REC...
Page 303: ...303 V2 0 02 11 El men REC ESPA OL...
Page 311: ...311 V2 0 02 11 Memorizaci n los valores de medici n ESPA OL...
Page 314: ...314 V2 0 02 11 Memorizaci n los valores de medici n...
Page 317: ...317 V2 0 02 11 Memorizaci n los valores de medici n ESPA OL...
Page 333: ......
Page 334: ......
Page 335: ......