Wedderburn Operator Manual
Page 11 of 12
WS202 Digital Bench Scale
7.
Trouble Shooting
Symptom
Possible Cause
Suggested Solution
Blank display when Power
ON/ZERO button is depressed
Discharged battery
Recharge the battery
Defective battery
Contact Wedderburn Online for
suitable replacement battery
Corroded battery
Clean connections
Power button not properly
depressed
Press Power On/Off firmly and hold
until power turns on.
“
- - - - - -
“
is display
The weight applied to the
weight pan is over 100%
maximum ca9e
Remove some or all of weight
“bATLo” is displayed
The battery voltage is low. Battery requires recharging.
Display reading not stable
The scale is in motion
Wait until the scale is stable
The load is not stable
Wait until the load is stable
Large error in weight reading
The scale is not zeroed
before applying load
Zero the scale before loading
Requires re-calibration
See section 7 for calibration
instructions
In correct weighing unit
lb/kg/g
Set correct measuring unit, see
section 5.9.2
In Counting mode (lamp on
over “PCS”
wording)
Scale will not enter calibration
mode (ERROR 2)
Calibration switch in
incorrect position
See section 7 for calibration
instructions