background image

9

CHECK FOR DAMAGED OR

WORN PARTS

Contact your authorized service dealer

for replacement of damaged or worn

parts.

S

ON/OFF

Switch -- Ensure switch functions

properly by moving the switch to the

OFF

position. Make sure motor stops; then re-

start motor and continue.

S

Inlet Cover -- Discontinue use of unit if in-

let cover fails to latch properly or if it is

damaged in any way.

AFTER EACH USE

INSPECT AND CLEAN UNIT & LABELS

Stop unit and unplug extension cord.

S

After each use, inspect complete unit

for loose or damaged parts. Clean the

unit using a damp cloth.

S

Wipe off unit with a clean dry cloth.

CLEAN COLLECTION BAG

IMPORTANT:

THE COLLECTION BAG

MUST BE PROPERLY EMPTIED.

D

You must properly empty and maintain

the collection bag to avoid deterioration

and obstruction of air flow.

D

Remove the collection bag from the unit

and empty after each use. Do not store

bag without emptying the bag of all con-

tents (grass, leaves, etc.).

D

Wash the bag once a year. Remove the

bag from the blower and turn the bag in-

side out. Wash the bag with a water hose.

Allow the bag to hang and dry completely

before you reuse the bag.

SERVICE

HOW TO REMOVE AN OBJECT

FROM THE AIR INTAKE

WARNING:

Stop the unit and dis-

connect from the power source before

opening the inlet cover. The motor must

be stopped and the impeller blades no

longer turning to avoid serious injury

from the rotating blades.

1. While holding the inlet cover open,

remove the vacuum tubes. The inlet

cover must be held open through all

remaining steps.

2. Carefully reach into the vacuum

opening and clear out the air intake

area. Clear all debris from impeller.

3. Inspect the impeller for cracks. If

cracked or damaged, do not use the

unit. Have parts replaced by your au-

thorized service dealer. Do not at-

tempt to replace them yourself.

STORAGE

WARNING:

Perform the following

steps after each use:

S

Stop unit and disconnect from the power

source.

S

Allow motor to cool before storing or

transporting.

S

Store unit with all guards in place. Posi-

tion unit so that any sharp object cannot

accidentally cause injury.

S

Store unit unplugged, well out of the

reach of children.

SEASONAL STORAGE

Prepare unit for storage at the end of

the season or if it will not be used for

30 days or more.

If your blower is to be stored for a period

of time:

S

Stop unit and disconnect from the power

source.

S

Clean the entire unit before lengthy stor-

age.

S

Open inlet cover and clean any dirt,

grass, or debris that has collected. In-

spect the blower and all tubes. Close and

make sure the cover is latched.

S

Clean air vents and air inlet of debris.

S

Store your unit and extension cord in a

well ventilated area and covered, if pos-

sible, to prevent dust and dirt accumula-

tion. Do not cover with plastic. Plastic can-

not breathe and may cause condensation

and eventual rust or corrosion.

S

Check entire unit for loose screws. Re-

place any damaged, worn, or broken

parts.

Summary of Contents for 545186754

Page 1: ...oduct Failure to do so can result in serious injury ADVERTENCIA Lea el manual de instrucciones y siga todas las advertencias e instrucciones de seguridad El no hacerlo puede resultar en lesiones graves AVERTISSEMENT Veuillez lire le manuel d instructions et bien respecter tous les avertissements et toutes les instructions de sécurité Tout défaut de le faire pourrait entraîner des blessures graves ...

Page 2: ... and moving parts Hair jewelry loose clothing or clothing with loosely hanging straps ties tassels etc can be caught in moving parts ELECTRICAL SAFETY WARNING Avoid a dangerous environment To re duce the risk of electrical shock do not use in rain in damp or wet locations or around swimming pools hot tubs etc Do not expose to snow rain or water to avoid the possibility of electrical shock Do not u...

Page 3: ...t injury resulting from an internal electrical insulation failure WARNING SERVICING OF DOUBLE INSULATED BLOWER VACUUM All electrical repairs to this unit including housing switch motor etc must be diag nosed and repaired by qualified service personnel Replacement parts for a double insulated appliance must be iden tical to the parts they replace A double in sulated appliance is marked with the wor...

Page 4: ... avoid severe damage to the impeller To avoid the possibility of electrical shock do not attempt to vacuum water or other liquids S Never run the unit without the proper equipment attached When used as a vacuum always install vacuum tubes and collection bag assembly Make sure the collection bag assembly is completely zipped when unit is running to avoid flying debris Use only recommended attach me...

Page 5: ...t restrictor is used when using your unit as a blower This restrictor is not used during vacuum use and must be removed during assembly for vacuum use NOTE Be sure to keep the inlet re strictor for using your unit as a blower 1 Ensure unit is stopped and extension cord is unplugged 2 Open the inlet cover by inserting the tip of a screwdriver into the latch area on the blower unit Gently tilt handl...

Page 6: ...position with the lower vacu um tube on the ground to support it 3 Place the shoulder strap over your head and onto your left shoulder 4 Adjust the strap to allow a free flow of air from the blower If the collection bag is kinked the unitwill notoperate properly NOTE The strap is designed to posi tion the collection bag on your shoulder without kinks The strap is not intended to support the weight...

Page 7: ...g the cord through the cord re tainer see illustration Insert the cord receptacle into the recessed plug CAUTION Failure to use cord retain er could result in damage to the unit extension cord or both Cord Retainer Cord Receptacle Recessed Plug on Unit USING YOUR UNIT KNOW YOUR ELECTRIC BLOWER VACUUM READ THIS INSTRUCTION MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT Compare the illustrations...

Page 8: ...r tube down or to one side Always work away from solid objects such as walks large stones vehicles and fences Clean corners by starting in corners and moving outward This will help prevent an accumulation of debris which could fly into your face Be careful when working near plants The force of the air could damage tender plants USING YOUR UNIT AS A VACUUM WARNING Do not vacuum stones gravel metal ...

Page 9: ... injury from the rotating blades 1 While holding the inlet cover open remove the vacuum tubes The inlet cover must be held open through all remaining steps 2 Carefully reach into the vacuum opening and clear out the air intake area Clear all debris from impeller 3 Inspect the impeller for cracks If cracked or damaged do not use the unit Have parts replaced by your au thorized service dealer Do not...

Page 10: ...aused by improper handling improper mainte nance or alteration or the use of accesso ries and or attachments not specifically recommended by WEED EATER for this product Additionally this warranty does not cover parts that will wear and require replacement with reasonable use during the warranty period This warranty does not cover predelivery set up or normal adjustments explained in the instructio...

Reviews: