147
CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
6.3 CONFIGURATION PARAMETERS - P200 to P399
P200
0 or 1
Password
[ 1 ]
-
Range
[Factory Setting]
Parameter
Unit
Description / Notes
The factory default for the password is P000 = 5.
To change the password refer to P000.
P201
(11)
0 to 3
Language Selection
[ - ]
-
Table 6.13 -
Password
Table 6.14 -
Language selection
P201
0
1
2
3
Language
Português
English
Español
Deutsch
P202
(1)(2)(11)
0 to 5
Type of Control
[ 0 (1) ]
-
P202
0
1
2
3
4
5
Type of Control
V/F 60 Hz
V/F 50 Hz
V/F Adjustable (Refer to P142 to P146)
Sensorless Vector
Vector with Encoder
VVW (Voltage Vector WEG)
For details on the Type of Control selection Refer to item 5.3.
Table 6.15 -
Type of control selection
It defines the selection type of special functions:
P203
(1)
0 or 1
Special Function
[ 0 ]
Selection
-
P203
Functions
0
Not Used
1
PID Regulator
Table 6.16 -
Special function selection
For the special function of PID regulator, refer to detailed description of
related parameters (P520 to P535).
When P203 is changed to 1, P265 is changed automatically to 15 -
Manual/Auto.
P200
0
1
Result
Disables the Password and allows
changing parameters content
independently of P000.
Enables the Password and allows
changing parameters content only when
P000 is set to the password value.
Function
Off
On