Vector Control
11-38
11
Seq.
Action/Result
Display Indication
20
At this point, the keypad
(HMI) presents the option to
run the
"Self-Tuning"
.
Whenever possible the Self-
Tuning must be carried out.
- Thus, press
"Select"
to
access P0408 and then
to select the
desired option. Refer to the
Item 11.8.5 Self-Tuning
[05] and [94] on page
11-23
, for more details.
- Next press "
Save
".
Config LOC
0rpm
13:48 Select
Motor Ventilation
P0406: Self-Vent.
Run Self-Tuning
P0408: No
21
- After doing that the Self-
Tuning routine is initiated
and
"SelfTun"
is indicated
on the top left corner of the
keypad (HMI).
- If the chosen option had
been the option 1, 2 or
3 in P0408, the keypad
(HMI) will present "
P0409:
Estimating Rs
".
SelfTun LOC
0rpm
13:48
P0409
Estimating Rs
[001] No Rotation
22
The keypad (HMI) will also
indicate the estimation of the
parameters P0411, P0410
and P0412 (if the option 1,
2 or 3 had been chosen in
P0408).
- When P0408 = 1 or 3
the keypad (HMI) will
not indicate the P0410
estimation.
- When P0408 = 3 or 4 the
keypad (HMI) will indicate
the P0413 estimation.
- Wait until the end of the
Self-Tuning routine.
SelfTun LOC
0rpm
13:48
P0411
Estimating
σ
ls
SelfTun LOC
0rpm
13:48
P0410
Estimating Im
SelfTun LOC
0rpm
13:48
P0412
Estimating Tr
SelfTun LOC
0rpm
13:48
P0413
Estimating Tm
23
Once the Self-Tuning routine
has finished, the inverter
returns to the monitoring
mode.
Ready
LOC
0rpm
13:48
Menu
0
rpm
4.0
A
0.0
Hz
Figure 11.7 -
Vector mode Oriented Start-up
Summary of Contents for CFW-11 Series
Page 2: ......
Page 54: ...2 4 2 General Information ...
Page 58: ...About the CFW 11 3 3 4 ...
Page 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Page 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Page 94: ...Available Control Types 8 2 8 ...
Page 118: ...VVW Control 10 8 10 ...
Page 182: ...Functions Common to All the Control Modes 12 26 12 ...
Page 220: ...Dynamic Braking 14 4 14 ...