Read Only Parameters [09]
16 READ ONLY PARAMETERS [09]
In order to facilitate the visualization of the main reading variables of the inverter, the group [09] - "Read Only
Parameters" can be accessed directly.
It is important to point out that all the parameters of that group can only be visualized on the keypad (HMI)
display, and that they do not allow changes by the user.
P0001 – Speed Reference
Adjustable
Range:
0 to 18000 rpm
Factory
Setting:
Properties:
RO
Access groups
via HMI:
09 READ ONLY PARAMETERS
Description:
This parameter presents, regardless of the origin source adjusted in P0221 or P0222, the value of the speed
reference in rpm (factory setting).
The indication unit can be modified from rpm to another unit through P0209, P0210 and P0211, as well as the
scale by means of P0208 and P0212.
It is also possible to change the speed reference (P0121) through this parameter, when P0221 or P0222 = 0.
P0002 – Motor Speed
Adjustable
Range:
0 to 18000 rpm
Factory
Setting:
Properties:
RO
Access groups
via HMI:
09 READ ONLY PARAMETERS
Description:
This parameter indicates the motor actual speed value in rpm (factory setting), with a 0.5 second filter.
The indication unit can be modified from rpm to another unit through P0209, P0210 and P0211, as well as the
scale by means of P0208 and P0212.
It is also possible to change the speed reference (P0121) through this parameter, when P0221 or P0222 = 0.
Summary of Contents for CFW-11 Series
Page 2: ......
Page 54: ...2 4 2 General Information ...
Page 58: ...About the CFW 11 3 3 4 ...
Page 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Page 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Page 94: ...Available Control Types 8 2 8 ...
Page 118: ...VVW Control 10 8 10 ...
Page 182: ...Functions Common to All the Control Modes 12 26 12 ...
Page 220: ...Dynamic Braking 14 4 14 ...