0
Quick Reference of Parameters, Alarms and Faults
CFW500 | 0-9
Parameter
Description
Adjustable
Range
Factory
Setting
User
Setting Properties
Groups
Page
P0275
DO1 Output Function
0 = Not Used
1 = F* > Fx
2 = F > Fx
3 = F < Fx
4 = F = F*
5 = Not Used
6 = Is > Ix
7 = Is < Ix
8 = Torque > Tx
9 = Torque < Tx
10 = Remote
11 = Run
12 = Ready
13 = No Fault
14 = No F0070
15 = Not Used
16 = No F0021/22
17 = Not Used
18 = No F0072
19 = 4-20 mA OK
20 = P0695 Value
21 = Clockwise Dir.
22 = Proc. V. > VPx
23 = Proc. V. < VPx
24 = Ride-Through
25 = Pre-Charge OK
26 = With Fault
27 = Not Used
28 = SoftPLC
29 = Not Used
30 = Not Used
31 = Not Used
32 = Not Used
33 = Not Used
34 = Not Used
35 = No Alarm
36 = No Fault/Alarm
37 = Function 1 Application
38 = Function 2 Application
39 = Function 3 Application
40 = Function 4 Application
41 = Function 5 Application
42 = Function 6 Application
43 = Function 7 Application
44 = Function 8 Application
13
I/O
P0276
DO2 Output Function
See options in P0275
2
I/O
P0277
DO3 Output Function
See options in P0275
0
I/O
P0278
DO4 Output Function
See options in P0275
0
I/O
P0279
DO5 Output Function
See options in P0275
0
I/O
P0287
Fx Hysteresis
0.0 to 500.0 Hz
0.5 Hz
I/O
P0288
Fx Speed
0.0 to 500.0 Hz
3.0 Hz
I/O
P0290
Ix Current
0.0 to 200.0 A
1.0xI
nom
I/O
P0293
Tx Torque
0 to 200 %
100 %
I/O
P0295
Inv. Rated Current
0.0 to 200.0 A
According to
inverter model
ro
READ
P0296
Line Rated Voltage
0 = 200 - 240 V
1 = 380 - 480 V
2 = 500 - 600 V
According to
inverter model
ro, cfg
READ
P0297
Switching Frequency
2500 to 15000 Hz
5000 Hz
P0299
Start Braking Time
0.0 to 15.0 s
0.0 s
P0300
Stop Braking Time
0.0 to 15.0 s
0.0 s
P0301
Start Frequency
0.0 to 500.0 Hz
3.0 Hz
P0302
DC Braking Voltage
0.0 to 100.0 %
20.0 %
P0303
Skip Frequency 1
0.0 to 500.0 Hz
20.0 Hz
Summary of Contents for CFW500 V1.8X
Page 2: ......
Page 4: ......
Page 8: ...Contents...
Page 34: ...General Information 2 4 CFW500...
Page 38: ...About the CFW500 3 4 CFW500 3...
Page 42: ...HMI and Basic Programming 4 4 CFW500 4...
Page 52: ...Programming Basic Instructions 5 10 CFW500 5...
Page 56: ...Identification of the Inverter Model and Accessories 6 4 CFW500 6...
Page 76: ...Available Motor Control Types 8 4 CFW500 8...
Page 84: ...V f Scalar Control 9 8 CFW500 9...
Page 170: ...Communication 17 8 CFW500 17...