Read only Parameters
16
CFW700 | 16-9
P0090 – Last Fault Current
Adjustable
Range:
0.0 to 4500.0 A
Factory
Setting:
Properties:
ro
Access groups
via HMI:
READ
Description:
It is the record of the current supplied by the inverter at the moment of the last fault occurrence.
P0091 – Last Fault DC Link Voltage
Adjustable
Range:
0 to 2000 V
Factory
Setting:
Properties:
ro
Access groups
via HMI:
READ
Description:
It is the record of the inverter DC link voltage at the moment of the last fault occurrence.
P0092 – Last Fault Speed
Adjustable
Range:
0 to 18000 rpm
Factory
Setting:
Properties:
ro
Access groups
via HMI:
READ
Description:
It is the record of the motor speed at the moment of the last fault occurrence.
P0093 – Last Fault Reference
Adjustable
Range:
0 to 18000 rpm
Factory
Setting:
Properties:
ro
Access groups
via HMI:
READ
Description:
It is the record of the speed reference at the moment of the last fault occurrence.