5
Programming Basic Instructions
CFW700 | 5-5
P0213 – Bar Graph Full Scale
Adjustable
Range:
1 to 65535
Factory
Setting:
1
Properties:
Access groups
via HMI:
HMI
Description:
This parameter sets the full scale of the Bar Graph parameter (selected by P0207).
P0216 – HMI Backlighting
Adjustable
Range:
0 to 15
Factory
Setting:
15
Properties:
Access groups
via HMI:
HMI
Description:
It allows setting the keypad (HMI) display contrast level. Higher values configure a higher contrast level.
5.5 DISPLAY INDICATIONS IN THE MONITORING MODE SETTINGS
Every time the inverter is powered the display goes to the Monitoring Mode. To facilitate reading the parameters
of the inverter, the display is designed to show three parameters at the same time according to the user's choice.
Two of these parameters (Main Display and Secondary Display) are shown in numerical form and the other in a
Bar Graph form. The selection of these parameters is done via P0205, P0206, P0207, as shown in
.
Inverter status
Secondary Display (selected by P0206).
Displays the content of parameter (Pxxxx),
value of parameter (Pxxxx), Fault indication
(Fxxx) or Alarm (Axxx).
Engineering Unit of the Main Display
(selected by P0209).
Main Display (selected by P0205).
Displays the content of parameter (Pxxxx),
value of parameter (Pxxxx), Fault indication
(Fxxx) or Alarm (Axxx).
Menu
Selection of parameter groups.
Bar Graph for parameter monitoring
(selected by P0207).
Figure 5.2:
Screen at startup and display indication
Summary of Contents for CFW700
Page 2: ......
Page 4: ......
Page 8: ...Summary...
Page 34: ...2 General Information 2 4 CFW700...
Page 38: ...3 About the CFW700 3 4 CFW700...
Page 56: ...7 Starting up and Settings 7 4 CFW700...
Page 58: ...8 Available Control Types 8 2 CFW700...
Page 78: ...10 VVW Control 10 8 CFW700...
Page 158: ...13 Digital and Analog Inputs and Outputs 13 28 CFW700...