English
TECHNICAL SPECIFICATIONS
8.1.2 Output
Table 8.2:
Inverter Output Data
Inverter smart code - items ”IV” and ”V”
Suffix number of phases and rated voltage
B2
T2
T4
Inverter output
Output voltage
-Single-phase AC power supply
0 ... Vin -5%
-Three-phase AC power supply
0 ... Vin -2%
-Power Supply CC
0 ... Vdc / 1.38
Output frequency
0 to 500 Hz for frame A...D
(1)
0 to 250 Hz for frame E
(1)
Rated output current
Io,nom (according to Tables 8.5, 8.6, 8.7 and 8.8)
Switching frequency
Rated (fsw,nom)
(2)
4 kHz
Frames A...D: 4 kHz
Frame E: 2 kHz
Adjustment range (fsw,usu)
(3)(4)
1...16 kHz
Frames A...D: 1.5...16 kHz
Frame E: 1...8 kHz
Maximum motor cable length
-No need to use output reactance
200 m (over 100 m it is necessary to use PWM modulation for long cables)
(5)
-With output reactance
500 m
-With sinusoidal filter on the inverter output
5000 m
Motor cable length to meet
IEC61800-3:2017 standard
0 ... 200 m (shielded according to IEC60034-25)
(1)
This output frequency range is valid considering the factory settings (e.g., rated switching frequency). It is possible to operate with higher
output frequencies, limited to 1000 Hz, but the rated switching frequency must be increased. In these cases, WEG must be consulted.
(2)
The switching frequency can be automatically reduced due to inverter output overload, high ambient temperature, obstruction of air
circulation around the heatsink and/or operation with low output frequency.
(3)
For operation with a switching frequency above the rated switching frequency (fsw,nom) it is necessary to reduce the output current according
to
(4)
Adjustable in 0.1 kHz steps.
(5)
The modulation type can be changed in parameter C1.4.1.
8.1.3
General Data
Table 8.3:
Inverter General Data
Inverter smart code - items ”IV” and ”V”
Suffix number of phases and rated voltage
B2
T2
T4
Dynamic Braking
Braking IGBT
(1)
Yes, included in the standard version
Frames A, B and C: yes, included in the standard version
Frames D and E: optional, models with DB suffix
RFI filter
Category C3, included in the standard version
(1)
The specifications for maximum braking current and minimum resistor resistance are indicated in
96 | CFW900
Summary of Contents for CFW900
Page 2: ......