INSTALLATION AND CONNECTION
Table 3.10:
Description of control connections
Item
Description
1
Connector (CFW900-IOS): digital and analog inputs and outputs, input for external power supply and RS-485 communication
2
Connector (safety module): STO and SS1-t functions
3
XC3 connector (microSD card slot): allows copying parameters and storing SoftPLC programs (see the programming manual)
4
XC4A and XC4B connectors: dual port ethernet connection (RJ45) (see the ethernet communication manual)
5
DIP switches S1 and S2: safety module configuration
6
XC6 connector: DB9 connector for connecting the HMI/remote HMI
7
Backplane
: provides four slots to connect accessories. By default, slot A is taken by the CFW900-REL-01. It
can be replaced by the CFW900-7SLOTS, which has seven slots for accessories
8
(CFW900-REL-01): Relay output
9
CR2032 battery for real time clock. Use non-conductive pliers or tweezers to remove/replace the battery
VIN (See 3.2.6.2)
GND
AI1-
AI1+
GND
10V
DI1
DI2
DI3
DI4
DI5
DI6
VOUT
DO1
AMP
RPM
GND
AO2
AO1
DO2
VOUT
1
2
3
4
5 6
7
8
9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24 25 26
COM
1 2 3 4
S3
(a)
Inputs configured in PNP mode (standard version)
VIN (See 3.2.6.2)
GND
AI1-
AI1+
GND
10V
DI1
DI2
DI3
DI4
DI5
DI6
GND
DO1
AMP
RPM
GND
AO2
AO1
DO2
VOUT
1
2
3
4
5 6
7
8
9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24 25 26
COM
S3
1 2 3 4
(b)
Inputs configured in NPN mode
Figure 3.20:
(a) and (b) Connection examples on XC1 (CFW900-IOS)
CFW900 | 39