DETAILED PARAMETER DESCRIPTION
m) Process variable Y < VPy
OFF
ON
ON
VPy (P0534)
Process
Variable
Relay/
Transistor
Time
Time
Figure 5.37:
(a) to (m) - Details on the operation of the digital output functions
✓
NOTE!
This parameter can be changed only with the motor stopped.
P0283 - RL2 ON time
P0284 - RL2 OFF time
P0285 - RL3 ON time
P0286 - RL3 OFF time
Adjustable range:
0.0 to 300.0 s
Factory setting:
0.0 s
Acesso:
Menu
→
Configurations
→
I/O
→
Digital outputs
Description:
Used in the relay output functions: Timers of relays 2 and 3.
P0288 - Nx Speed
P0289 - Ny Speed
Adjustable range:
0 to 4095 rpm
Factory setting:
P0288 = 120 rpm
P0289 = 1800 rpm
Acesso:
Menu
→
Configurations
→
Control
Description:
Used in the digital and relay output functions: N* > Nx, N > Nx and N < Ny.
P0290 - Ix Current
Adjustable range:
0.0 to 3276.7 A
Factory setting:
300.0 A
Acesso:
Menu
→
Configurations
→
Control
Description:
Used in the digital and relay output functions: Is > Ix and Is < Ix.
P0291 - Zero Speed Zone
Adjustable range:
1 to 100 %
Factory setting:
1 %
Acesso:
Menu
→
Configurations
→
Control