background image

WEG Worldwide Operations

68

C

41

03

H

01

 

R

ev

: 0

0 | D

at

e (m

/y

): 0

3/

20

17

Th

e v

al

ue

s s

ho

w

n a

re s

ub

je

ct t

o c

ha

ng

e w

ith

ou

t p

rio

r n

ot

ic

e. 

 

WEG Group - Automation Business Unit

 

Jaraguá do Sul - SC - Brazil  

 

Phone: +

55 (47) 3276-4000 

 

automacao@weg.net 

 www.weg.net 

ARGENTINA

San Francisco - Cordoba
Phone: +54 3564 421484

info-ar@weg.net

Cordoba - Cordoba
Phone: +54 351 4641366

weg-morbe@weg.com.ar

Buenos Aires
Phone: +54 11 42998000

ventas@pulverlux.com.ar

AUSTRALIA

Scoresby - Victoria 
Phone: +61 3 97654600

info-au@weg.net

AUSTRIA

Markt Piesting - Wiener 
Neustadt-Land
Phone: +43 2633 4040

watt@wattdrive.com

BELGIUM

Nivelles - Belgium
Phone: +32 67 888420

info-be@weg.net

BRAZIL

Jaraguá do Sul - Santa 
Catarina
Phone: +55 47 32764000

info-br@weg.net

CHILE

La Reina - Santiago
Phone: +56 2 27848900

info-cl@weg.net

CHINA

Nantong - Jiangsu
Phone: +86 513 85989333

info-cn@weg.net

Changzhou – Jiangsu 
Phone: +86 519 88067692

info-cn@weg.net

COLOMBIA

San Cayetano - Bogota
Phone: +57 1 4160166

info-co@weg.net

ECUADOR

El Batan - Quito
Phone: +593 2 5144339

ceccato@weg.net

FRANCE

Saint-Quentin-Fallavier - Isère
Phone: +33 4 74991135

info-fr@weg.net

GERMANY

Türnich - Kerpen 
Phone: +49 2237 92910

info-de@weg.net

Balingen - Baden-
Württemberg
Phone: +49 7433 90410

info@weg-antriebe.de

GHANA

Accra
Phone: +233 30 2766490

info@zestghana.com.gh

INDIA

Bangalore - Karnataka
Phone: +91 80 41282007

info-in@weg.net

Hosur - Tamil Nadu
Phone: +91 4344 301577

info-in@weg.net

ITALY

Cinisello Balsamo - Milano
Phone: +39 2 61293535

info-it@weg.net

JAPAN

Yokohama - Kanagawa
Phone: +81 45 5503030

info-jp@weg.net

MALAYSIA

Shah Alam - Selangor
Phone: +60 3 78591626

info@wattdrive.com.my

MEXICO

Huehuetoca - Mexico
Phone: +52 55 53214275

info-mx@weg.net

Tizayuca - Hidalgo
Phone: +52 77 97963790

NETHERLANDS

Oldenzaal - Overijssel
Phone: +31 541 571080

info-nl@weg.net

PERU

La Victoria - Lima
Phone:  +51 1 2097600

info-pe@weg.net

PORTUGAL

Maia - Porto
Phone: +351 22 9477700

info-pt@weg.net

RUSSIA and CIS

Saint Petersburg
Phone: +7 812 363 2172

sales-wes@weg.net

SOUTH AFRICA

Johannesburg
Phone: +27 11 7236000

info@zest.co.za

SPAIN

Coslada - Madrid
Phone: +34 91 6553008

wegiberia@wegiberia.es

SINGAPORE

Singapore
Phone: +65 68589081

info-sg@weg.net 

Singapore
Phone: +65 68622220

watteuro@watteuro.com.sg

SCANDINAVIA

Mölnlycke - Sweden
Phone: +46 31 888000

info-se@weg.net

UK

Redditch - Worcestershire
Phone: +44 1527 513800

info-uk@weg.net

UNITED ARAB EMIRATES

Jebel Ali - Dubai
Phone: +971 4 8130800

info-ae@weg.net

USA

Duluth - Georgia
Phone: +1 678 2492000

info-us@weg.net 

Minneapolis - Minnesota
Phone: +1 612 3788000

VENEZUELA

Valencia - Carabobo
Phone: +58 241 8210582

info-ve@weg.net

For those countries where there is not a WEG own operation, find our local distributor at www.weg.net.

Summary of Contents for UBW400

Page 1: ...Motors Automation Energy Transmission Distribution Coatings User s Manual WEG Molded Case Circuit Breakers UBW400 ...

Page 2: ...lating to the safety of personnel and equipment as well as all general and local health and safety laws codes and procedures The recommendations and information contained herein are based on WEG experience and judgment but should not be considered to be all inclusive or covering every application or circumstance which may arise If any questions arise contact WEG for further information or instruct...

Page 3: ...e for the intended installation by comparing nameplate data with existing equipment ratings and system requirements Inspect the circuit breaker for completeness and check for damage before mounting Uninstalled cover mounting hardware is supplied in a plastic bag with the circuit breaker frame see Figure 2 and Table 2 Flat head thread forming screws Pan head screws Figure 2 cover mounting hardware ...

Page 4: ...b in 2 2 6 N m 5 If not already installed mount terminals as shown in Figure 4 Secure the terminals to the circuit breaker using a 7 32 inch socket wrench and torque to 6 8 lb ft 8 11 N m After mounting the circuit breaker and before installation of the conductors the terminal mounting screw can be checked or retightened through the terminal when the conductor screw is removed If warning label is ...

Page 5: ...no voltage is present NOTICE Depending on the equipment configuration the circuit breaker can be mounted using different styles of hardware The following steps describe how to mount the circuit breaker using standard hardware When special hardware is needed for example with the electrical operator the instruction leaflet describing the accessory also describes the special mounting arrangements 6 T...

Page 6: ... Figure 6 circuit breaker escutcheon dimensions for 3 pole circuit breakers b If circuit breaker includes factory or field installed internal accessories make sure accessory wiring can be reached when the circuit breaker is mounted c Position circuit breaker on mounting surface NOTICE Labels with accesory connection schematic diagrams are provided on the side of the circuit breaker A note should b...

Page 7: ...Cat No LT3UBW400 are used terminal shields supplied with the terminals must be installed on the circuit breaker Figure 7 Warning label supplied with the kit must be attached to the circuit breaker front cover Mounting slots Terminal cover Dovetails Figure 7 terminal cover installation 9 If required install terminal shield on circuit breaker cover with mounting screws provided 10 After the circuit ...

Page 8: ...e Figure 8 Push to trip Button Thermal magnetic Trip unit adjustment Button 3 places Handle position indicator Color Red White Green On Trip Off reset On On Trip Off Reset Off International Symbols Figure 8 circuit breaker manual controls 3 2 CIRCUIT BREAKER RESET After an automatic or accessory initiated trip or a manual PUSH TO TRIP operation the circuit breaker is reset by moving the circuit br...

Page 9: ...ing Adjustment buttons Figure 9 trip unit magnetic adjustment buttons 4 INSPECTION AND FIELD TESTING UBW400 molded case circuit breakers are designed to provide years of almost maintenance free operation The following procedure describes how to inspect and test a circuit breaker in service 4 1 INSPECTION AND FIELD TESTING Circuit breakers in service should be inspected periodically The inspection ...

Page 10: ... installed 6 Check circuit breaker mounting hardware and tighten if necessary 7 Check area where circuit breaker is installed for any safety hazards inlcuding personal safety and fire hazards Exposure to certain types of chemicals can cause deterioration of electrical connections 4 2 FIELD TESTING Any field testing should be done in accordance with applicable NEMA Standard The instructions for ins...

Page 11: ...e to the purchaser or user in contract in tort including negligence strict liability or otherwise for any special indirect incidental or consequential damage or loss whatsoever including but not limited to damage or loss of use of equipment plant or power system cost of capital loss of power additional expenses in the use of existing power facilities or claims against the purchaser or user by its ...

Page 12: ... Phone 233 30 2766490 info zestghana com gh INDIA Bangalore Karnataka Phone 91 80 41282007 info in weg net Hosur Tamil Nadu Phone 91 4344 301577 info in weg net ITALY Cinisello Balsamo Milano Phone 39 2 61293535 info it weg net JAPAN Yokohama Kanagawa Phone 81 45 5503030 info jp weg net MALAYSIA Shah Alam Selangor Phone 60 3 78591626 info wattdrive com my MEXICO Huehuetoca Mexico Phone 52 55 53214...

Reviews: