9�4�2
Replacement of the retaining ring (Pos� 5) of connectors with the sealing range
up to Ø15�8 mm
Î
Move the clamping lever (Pos. 2) to the straight starting position. The clamping
jaws (Pos. 9) and the front seal (Pos. 7) must be relaxed.
Î
Slightly push two clamping
jaw segments (Pos. 9)
apart with the
WEH
®
O-ring picker so that a
small gap is created.
Î
Insert the WEH
®
O-ring picker
into the gap and lift the
retaining ring (Pos. 5).
Î
Roll the retaining ring over the
shaft (Pos. 11).
Î
Let the loose clamping jaws (Pos. 9) fall off the connector.
Î
Check the clamping jaws for damage. If they are damaged, replace the clamping
jaws.
Î
Roll the new
retaining ring (Pos. 5) over
the shaft (Pos. 11) into the
area between the
retainer plate (Pos. 8) and the
spacer (Pos. 10).
Gap
MD-10015-L51-R1.1.0-03
Page 24
Operating instructions