Î
Pull lightly on the connector in the direction opposite that of the connection to make
sure that the connector is firmly in place.
- The connector is now connected pressure-tight to the cylinder valve.
Î
Open the cylinder valve.
Î
To start the filling procedure, apply pressure to media inlet “B1”.
Attention:
The safety peg (pos. 5) at the connector must be extended after pressure
is applied. The actuator is blocked, the connector cannot be disconnected when it is
pressurized.
Connecting a TW54 with bail actuation, flexible wire rope and locking device
Î
Press the locking device (pos. 8) upwards (
).
Î
Fold the bail actuation (pos. 6) downwards. The flexible
wire rope will fold upwards and the clamping jaws will
close together (
).
Î
Insert the connector loosely and straight into the cylinder
valve until a noticeable seal contact has been established
(
). Doing so will prevent any damage to the front
seal caused by any sharp edges on the cylinder valve and
ensure a correct connection.
Attention:
Make sure that the connector is pressed onto
the cylinder valve until a noticeable seal contact has been
established.
Note:
Insert the connector with RPV pin into the cylinder
valve until the RPV pin is pushed open in the cylinder valve
and the sealing piston creates a seal.
Figure 7
Figure 8
Figure 9
MD-10017-L51-R2.1.0-03