Installation
40
Figure 3.6 - Vibration absorber arrangement
If the engine works in a soundproof box, sealing rubber should be installed around the
radiator to prevent the hot air beyond the engine from flowing back into the cool air
entrance.
Radiator grounding measures must be taken to eliminate potential difference and prevent
electrical corrosion (aluminum radiator do not require).
The surface of the radiator should not be covered by other components, and the direct
wind crossing area should be greater than 80% of the radiator surface.
The minimum diameter of the coolant pipe between the pump and radiator is: 100mm
(inlet of high temperature circuit), 80mm (outlet of high temperature circuit), 84mm (inlet
of low temperature circuit), and 60mm (outlet of low temperature circuit).
The minimum distance from fan front-end to radiator is 150mm.
The coolant capacity of the engine (W/O radiator) is approx.100L.
3.7 Lubrication System
Users must follow the requirements in
6.2 Lubricant Recommendation.
To get a good performance of the engine lubricant system, the engine should be mounted on
the chassis within a permitted angle. The angle limitation is 5
°
in front-rear direction and 15
°
in left-right direction.
3.8 Gas Supply System
The installation of the gas supplying system must comply with the following requirements:
The typical gas supplying system arranged as :