Operation and Maintenance Manual and User Service Guide for Industrial Power WP10 Series Diesel Engine
20
4. Maintenance specifications for industrial engines
Maintenance intervals and specifications of industrial engines are suitable for
P4, P6, 10L, 12L, 13L and Baudouin series.
4.1 Maintenance intervals and specifications of industrial engines
4.1.1 Maintenance intervals of industrial diesel engines
Initial maintenance ( P ) New engine running for 30-50h
Level 1 maintenance (WD1) Diesel engine running interval 250h
Level 2 maintenance (WD2) Diesel engine running interval 500h
Level 3 maintenance (WD3) Diesel engine running interval 1000h
Level 4 maintenance (WD4) Diesel engine running interval 3000h
4.1.2 Daily maintenance for diesel engine
4.1.2.1 With diesel engine running, always note that the oil temperature, oil
pressure and coolant temperature at outlet, and check for “three
-
leakage”
(oil, gas and water). In case of any abnormal, find out the cause for
troubleshooting.
4.1.2.2 After the diesel engine is stopped, check the fuel, fresh-water coolant
and oil capacity, if needed, refill it.
4.1.2.3 Drain the water in the stage-one fuel filter.
4.1.2.4 Check the tension of belts, adjust it if necessary.
4.1.2.5 If the ambient temperature is less than 0
℃
, and the diesel engine is
not filled with antifreeze, drain the coolant to prevent the diesel engine
parts from being froze.
4.1.2.6 Check oil level in the fuel injection pump and governor, if needed,
refill it properly.