background image

 

- 8 - 

“Turbo Ring” DIP Switch Settings 

DIP 1 

DIP 2 

DIP 3 

DIP 4 

Reserved for 
future use. 

ON: Enables this 
Ethernet Switch 
as the Ring 
Master. 

ON: Enables the 
default “Ring 
Coupling” ports. 

ON: Activates 
DIP switches 1, 
2, 3 to configure 
“Turbo Ring” 
settings. 

 

“Turbo Ring V2” DIP Switch Settings   

DIP 1 

DIP 2 

DIP 3 

DIP 4 

ON: Enables the 
default “Ring 
Coupling 
(backup)” port. 

ON: Enables this 
Ethernet Switch 
as the Ring 
Master. 

ON: Enables the 
default “Ring 
Coupling” port. 

ON: Activates 
DIP switches 1, 
2, 3 to configure 
“Turbo Ring V2” 
settings. 

OFF: Enables the 
default “Ring 
Coupling 
(primary)” port. 

OFF: This 
Ethernet Switch 
will not be the 
Ring Master. 
 

OFF: Do not use 
this Ethernet 
Switch as a ring 
coupler. 

OFF: DIP 
switches 1, 2, 3 
will be disabled. 

 

NOTE

 

You must enable the Turbo Ring function first before using the DIP 
switch to activate the Master and Coupler functions. 

 

NOTE

 

If you do not enable any of the Ethernet switches to be the Ring 
Master, the Turbo Ring protocol will automatically choose the 
switch with the smallest MAC address range to be the Ring Master. 
If you accidentally enable more than one switch to be the Ring 
Master, these switches will auto-negotiate to determine which one 
will be the Ring Master. 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for IE-SW-PL06M-2TX-4PoE

Page 1: ...1254050000 01 10 12 Please note This document the detailed manual and any further product information if available can be downloaded at the internet link http www weidmueller com downloads Copyright N...

Page 2: ...ecially for security automation applications such as IP surveillance and gate of entry systems which can benefit from a scalable backbone construction and Power over Ethernet support The switch can op...

Page 3: ...ifices 4 Console port 5 DIP switches 6 Power input PWR1 LED 7 Power input PWR2 LED 8 Fault LED 9 MSTR HEAD LED indicator 10 CPLR TAIL LED indicator 11 Label 12 TP port s 100 Mbps LED 13 TP port s 10 M...

Page 4: ...the DIN Rail attachment plate to the switch make sure the stiff metal spring is situated towards the top as shown by the following figures STEP 1 Insert the top of the DIN Rail into the slot just bel...

Page 5: ...late the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratin...

Page 6: ...AULT The two sets of relay contacts of the 6 pin terminal block connector are used to detect user configured events The two wires attached to the fault contacts form an open circuit when a user config...

Page 7: ...Ethernet switch The proprietary Turbo Ring protocol was developed to provide better network reliability and faster recovery time Turbo Ring s recovery time is less than 300 ms Turbo Ring or 20 ms Tur...

Page 8: ...bo Ring V2 settings OFF Enables the default Ring Coupling primary port OFF This Ethernet Switch will not be the Ring Master OFF Do not use this Ethernet Switch as a ring coupler OFF DIP switches 1 2 3...

Page 9: ...ter of the Turbo Ring or the Head of the Turbo Chain after the Turbo Ring or the Turbo Chain is down Off When the switch is not the Master of this Turbo Ring or is set as the Member of the Turbo Chain...

Page 10: ...odbus TCP LLDP IEEE 1588 PTP IPv6 MIB MIB II Ethernet Like MIB P BRIDGE MIB Q BRIDGE MIB Bridge MIB RSTP MIB RMON MIB Group 1 2 3 9 Forwarding and Filtering Rate 148810 pps Processing Type Store and F...

Page 11: ...rms as described in the general conditions of sale of the Weidm ller company which has sold the products to you Weidm ller warrants to you that such products the defects of which have already existed...

Page 12: ...nformation Weidm ller Interface GmbH Co KG Postfach 3030 32760 Detmold Klingenbergstra e 16 32758 Detmold Germany Phone 49 0 5231 14 0 Fax 49 0 5231 14 2083 E Mail info weidmueller com Internet www we...

Reviews: