- 10 -
If neither of these two conditions occurs, the Fault circuit will be closed.
DIP Switch Settings
The default setting for each DIP switch is OFF. The
following table explains the effect of setting the DIP
switches to the ON positions.
DIP Switch
Setting
Description
BSP
ON
Enables broadcast storm protection
OFF
Disables broadcast storm protection
----
refers to Jumbo
Frame
ON
Enables jumbo frame function
OFF
Disables jumbo frame function
PORT Alarm
ON
Enables the corresponding PORT Alarm. If the
port’s link fails, the relay will form an open circuit
and the fault LED will light up.
OFF
Disables the corresponding PORT Alarm. The
relay will form a closed circuit and the Fault LED
will never light up.
ATTENTION
To actively update DIP switch settings, power off and then power
on the Ethernet Switch.
LED Indicators
The front panel of the Ethernet Switch contains several LED indicators. The
function of each LED is described in the table below.
LED
Color
State
Description
PWR1
AMBER
On
Power is being supplied to power input
PWR1
Off
Power is
not
being supplied to power input
PWR1
PWR2
AMBER
On
Power is being supplied to power input
PWR2
Off
Power is
not
being supplied to power input
PWR2
FAULT
RED
On
When the corresponding PORT alarm is
enabled, and the port’s link is inactive.