Wi-Fi device IE-WL-VL-AP-BR-CL
Web Console Configuration
3-55
Saving configuration to
EBR-MODULE
RS232
The configuration is successfully saved/there is an error saving the
configuration to
EBR-MODULE RS232
.
EBR-MODULE RS232
failure
IE-WL-VL-AP-BR-CL cannot detect an
EBR-MODULE RS232
at
the console port.
Configuration reset to default
The configuration is reset to factory default.
Power events
Event is triggered when…
Power 1/2 transition (On -> Off)
The IE-WL-VL-AP-BR-CL is powered down in PWR1/2.
PoE transition (On -> Off)
The IE-WL-VL-AP-BR-CL is powered down in PoE.
Power 1/2 transition (Off -> On)
The IE-WL-VL-AP-BR-CL is powered via PWR1/2.
PoE transition (Off -> On)
The IE-WL-VL-AP-BR-CL is powered via PoE.
Syslog
This function provides the event logs for the Syslog server. The function supports up to three configurable
Syslog servers and Syslog server UDP port numbers. When an event occurs, the event will be sent as a Syslog
UDP packet to the specified Syslog servers.
Syslog Event Types
Detailed information for the grouped events is shown in the following table. Check the box for
Enable logging
to enable the grouped events. All default values are enabled (checked). Detailed descriptions of the event types
are available in the
System Logs
section.
Syslog Server Settings
You can configure the parameters for your Syslog servers in this page.
Syslog server 1/ 2/ 3
Setting
Description
Factory Default
IP address
Enter the IP address of the 1st/ 2nd/ 3rd Syslog Server
None
Syslog port
Setting
Description
Factory Default
Port destination
(1 to 65535)
Enter the UDP port of the corresponding Syslog server
514