5.14 Programming structure
Name
Authorization
1)
Options
Default
Description
1. Production menu
I
2. Wiring data
I
3. User menu
I
4. USB data
II
5. Programs
II
6. Settings
Language
II
German / English /
French
English
Short program
II
1 / 0
1
1 standard parameter modifiable
0 further parameters modifiable
Memory locations program
II
1 ... 2000
Subdivision of program positions
Cable monitoring
II
1 / 0
1
Cable between feed rollers
0-cut
II
1 / 0
1
Zero-overlap cut at program start
PC start
II
1 / 0
0
Start command via WI manager
Ramp motor
II
1-10
5
Ramping up after switch-on
1= fast, 10 = slow
Speed
II
0.1 ... 1.5 m/s
1.5
Feed speed of the cable feed
Correction
II
-99...+99 mm
Length correction of cable feed
Timeout position
III 0 ... 99 s
50
Program waiting time
III 0 ... 100 s
Motor increments
III 1 ... 9999 inc/U
2000
Path/Motor rpm
III 1 ... 999.9999 mm per
turn
36.4425
Max. power feed
III 0 ... 255
95
Max. power cutting
III 0 ... 255
50
Machine type
Machine number
7. Operating data
II
Delete day counter
III Delete all programs
III Factory settings
8. Manual operation
III
9. Test inputs
III
10. Test outputs
III