74
Control.ini
With the combination of the input event, it looks like this:
!i1c!ess1001#
You can assign several commands to an input event. In this
case, attach the additional commands. The total number of
characters of a command line must not exceed 150 characters.
For example with the line
!i1c!ess1001!edv10:255#
If input 1 is closed, the
outputs 1 and 4 will
be activated and additionally the
channel 10 will be set to
255.
9.1.5 !d: DMX events
The whole
univers can also be used as a start condition
for a command. As operators
> < =
are permitted.
Example:
!d1=255!...#
-> If the value of the
channel 1 is equal
255, then the downstream command will be executed.
!d150<20!...#
-> If the value of the
channel 150 is
less than 20, then the downstream command will be executed.
!d512>175!...#
-> If the value of the
channel 512
is greater than 175, then the downstream command will be
executed.