80
Control.ini
9.2.3 Project 3 – Three shows alternate in an interval
of 90 minutes between 8 a.m. in the morning
till 2 a.m. in the night
The project consists of three different show files, which
are played in an interval of 90 minutes between 8 a.m. in the
morning till 2 a.m. in the night. But only, if the key switch, which
is connected to input 1 is closed. The first show starts at 8 a.m.
sharp, the second show at 8:30 a.m. and the third show at 9
a.m. sharp. Afterwards the first show starts at 9:30 a.m. again.
The procedure will be continued till 2 a.m. sharp of the following
day.
The content of the Control.ini file looks like this:
!i1c!vmc1=1#
!i1o!vmc1=0#
!rc(h>7;m=0)!vmc2+1#
!rc(h>7;m=30)!vmc2+1#
!rc(h<3;m=0)!vmc2+1#
!rc(h<2;m=30)!vmc2+1#
!vcc1=1!vcc2=1!rsn1#
!vcc1=1!vcc2=2!rsn2#
!vcc1=1!vcc2=3!rsn3#
!vcc2=3!vmc2=0#
1
st
line: If input 1 is activated (
!i1c
), then the value of variable
1 will attain 1 (
!vmc1=1
).
2
nd
line: If input 1 is disabled (
!i1o
), then the value of variable
1 will attain 0 (
!vmc1=0
).
Summary of Contents for ProCommander LTC
Page 1: ...Weigl ProCommander LTC Instruction Manual...
Page 6: ......
Page 27: ...27 Pin assignment ProCommander LTC Jumper open Jumper closed...
Page 31: ...31 USB driver installation...
Page 54: ...54 Modification of the menu of ProCommander LTC...
Page 68: ...68 Variable...
Page 92: ...92 Control ini...
Page 98: ...98 Programming the ProCommander LTC...
Page 104: ...104 Network connection between ProCommander LTC and Pro I O...
Page 106: ...106 Interface protocols...
Page 108: ...108 Videoplayer Configuration...
Page 118: ...118 Videoplayer Configuration...
Page 124: ...124 Appendix...
Page 126: ...126 Glossary...
Page 128: ...128 F A Q...