CCD Commissioning
To make CCD ready for machining, you need to adjust the camera and do some
commissioning.
Follow steps below to do the commissioning.
1.
Power up and start the NC system.
2.
Turn the system to
Homing
mode, and return all machine axes to the machine
origin.
3.
Turn the system to
Manual
mode, Click
Vision
→
CCD
→
Parameters
→
Manufacturer Param
→
Measure
to switch to
Measure
interface.
4.
Use the function
Pick Current
to decide the working plane.
It is recommended to leave distance between the camera bottom to the
workpiece surface 125mm.
See Setting CCD Working Plane for details.
5.
Adjust the camera, including the
focal length
,
aperture
, etc. to ensure the
camera can get a clear sight.
6.
Measure the magnification of the camera
.
7.
Move to the shooting position.
8.
Camera shoots and
gets marking points
.
Setting CCD Related Parameters
To make CCD ready for machining, you need firstly set related parameters, including
parameters of different access.
Prerequisite
All machine axes have returned to the machine origin.
Steps
To set CCD related parameters:
1.
Click
Vision
→
CCD
→
Parameters
. It opens dialog box titled "Machine Vision
Parameter".
WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
- 10 -