Part number 550-100-213/1220

2

Please read this page fi rst

  

CONDENSING

 

GAS

 

BOILER

 — 

 U

SER

S

 I

NFORMATION

 Manual

 Condensate

trap and drain 

(drain line must be 

installed by quali-

fi ed technician, per 

boiler manual)

asy

Pressure/temperature 

gauge

Relief valve

Control display

and buttons

Relief valve drain line (must be run to safe 

drainage location — must be installed by qualifi ed 

technician, per boiler manual)

MANUAL GAS VALVE

Piping to system

Piping from system

Hazard defi nitions

The following defi ned terms are used throughout this 

manual to bring attention to the presence of hazards of 

various risk levels or to important information concerning 

the life of the product.

Indicates presence of hazards that will cause 

severe personal injury, death or substantial 

property damage.

Indicates presence of hazards that can cause 

severe personal injury, death or substantial 

property damage.

Indicates presence of hazards that will or can 

cause minor personal injury or property damage.

Indicates special instructions on installation, 

operation or maintenance that are important 

but not related to personal injury or property 

damage.

To . . .

Read and use . . .

Page

Locate boiler

components

See illustration at right

2

Learn

precautions

See Hazard Defi nitions, below

2

Read before

proceeding

Additional information

3

Prevent air

contamination

Laundry room or pool

 — make 

sure boiler air is piped to boiler per 

manual.

Read list of air contaminants you 

must avoid. 

Have boiler air re-piped 

to another location if you can’t 

avoid.

4

Maintain

boiler

Set up a 

plan for maintaining the 

boiler

 using the schedule included in 

this manual.

Schedule an 

annual start-up

 by a 

qualifi ed service technician before 

every heating season.

5

Start — or —

Shut down

boiler

Follow the 

Operating instruction

sheet details to start or shut down 

your boiler.

9

Understand 

control
display

This page shows display screen 

modes and menu access information.

10

This page shows how to access the 

USER MENU to set date and time 

and reset faults if the boiler enters 

LOCKOUT.

11

 Evergreen Boiler components

ON/OFF Switch 

(on side)

Summary of Contents for 383900000

Page 1: ... the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any telephone in your building Immediately call your gas supplier from a neighbor s telephone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation service must be performed by a qualifi...

Page 2: ...substantial property damage Indicates presence of hazards that will or can causeminorpersonalinjuryorpropertydamage Indicates special instructions on installation operation or maintenance that are important but not related to personal injury or property damage To Read and use Page Locate boiler components See illustration at right 2 Learn precautions See Hazard Definitions below 2 Read before proc...

Page 3: ...t block flow of combustion or ventilation air to boiler This boiler is equipped with a control which will automatically shut down the boiler should air or vent be blocked If vent or air blockage is easily ac cessible and removable remove it The boiler should attempt to restart within an hour If blockage is not obvious or cannot be removed have the boiler and system checked by a qualified service t...

Page 4: ...ed to fasten building products and other similar products Excessive dust and dirt Areas likely to have contaminants Dry cleaning laundry areas and establishments Swimming pools Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishments New building construction Air contaminatio...

Page 5: ...uge Verify boiler jacket door is securely closed MONTHLY Check vent piping Check air piping Check relief valve Check condensate drain system Check automatic air vents if used Check display date and time EVERY 6 MONTHS Check boiler piping gas and water Operate relief valve Follow the service and maintenance procedures given throughout this manual and in component literature shipped with the boiler ...

Page 6: ...heck boiler pressure temperature gauge 1 Make sure the pressure reading on the boiler pressure temperature gauge does not exceed 24 psig if using a 30 psig relief valve typical installation Higher pressure may indicate a problem with the expansion tank 2 Contact a qualified service technician if problem persists Verify that front door is securely closed 1 Visually inspect front door to be sure it ...

Page 7: ...mitted into the boiler room through the condensate drain line or tee Follow procedure below to fill trap 3 Verify that the condensate drain line is unob structed by slowly pouring water into the top of the PVC tee on the side of the boiler The water should run out the end of the condensate drain line If the water does not run out call your qualified service technician to inspect the boiler and cle...

Page 8: ... slightly al lowing water to relieve through the valve and discharge piping 4 If water flows freely release the lever and allow the valve to seat Watch the end of the relief valve discharge pipe to ensure that the valve does not weep after the line has had time to drain If the valve weeps lift the seat again to attempt to clean the valve seat If the valve continues to weep afterwards contact your ...

Page 9: ...Part number 550 100 213 1220 9 OPERATING INSTRUCTIONS CONDENSING GAS BOILER USER S INFORMATION Manual Figure 5 Operating instructions see page 2 for location of manual gas valve ...

Page 10: ...Part number 550 100 213 1220 10 The Evergreen control display CONDENSING GAS BOILER USER S INFORMATION Manual Figure 6 EvergreenTM boiler control display states ...

Page 11: ... BOILER USER S INFORMATION Manual Resetting faults 1 During a fault the status will change to LOCKOUT and the Time Date line will alternate with the fault name The line MANUAL RESET will appear on the Boiler Status screen 2 Select MANUAL RESET to reset fault condition 3 The MANUAL RESET screen will indicate whether the fault was a manual or automatic reset the fault name and the time and date it o...

Page 12: ...Part number 550 142 123 0513 CONDENSING GAS BOILER USER S INFORMATION Manual ...