Part number 550-100-213/1220

3

 STOP!! — Read before proceeding

  

CONDENSING

 

GAS

 

BOILER

 — 

 U

SER

S

 I

NFORMATION

 Manual

Have this boiler serviced/

inspected by a qualified 

service technician, at least 

annually.

 

Failure to comply with the above 

could result in severe personal 

injury, death or substantial prop-

erty damage.

  When calling or writing about the 

boiler— Please have the boiler 

model number from the boiler 

rating label and the CP number 

from the boiler cabinet.

• 

Should overheating of boiler occur or gas sup-
ply fail to shut off

DO NOT

 turn off or disconnect 

electrical supply to circulator. Instead, shut off the gas 
supply at a location external to the appliance.

• 

Do not use this boiler if any part has been 
under water

. Immediately call a qualifi ed service 

technician to inspect the boiler and to replace any part 
of the control system and any gas control that has been 
under water.

Failure to adhere to the guidelines on this page can result in severe 

personal injury, death or substantial property damage

.

Boiler service and maintenance —

•  To avoid electric shock, 

interrupt electrical 

supply

 before performing maintenance.

•  To avoid severe burns, 

allow boiler to cool

 before 

performing maintenance.

•  You must 

maintain

 the boiler as outlined in the 

manual and have the boiler 

started up and ser-

viced at least annually by a qualifi ed ser-

vice technician

 to ensure boiler/system reliability.

Boiler operation —

•  Do not block fl ow of combustion or ventilation air to 

boiler. This boiler is equipped with a control which 
will automatically shut down the boiler should air or 
vent be blocked. If vent or air blockage is easily ac-
cessible and removable, remove it. The boiler should 
attempt to restart within an hour. If blockage is not 
obvious or cannot be removed, have the boiler and 
system checked by a qualifi ed service technician.

Combustion air —

• 

DO NOT obstruct the combustion air intake or 

expose the air intake to corrosive chemicals 

(see next page).

Carbon monoxide detector —

•  A carbon monoxide detector that is wired on the 

same electrical circuit as the boiler is strongly recom-

mended.

Boiler water —

•  Do not use petroleum-based cleaning or sealing 

compounds in boiler system. Gaskets and seals in the 

system may be damaged. This can result in substantial 

property damage.

• 

Leaks in boiler or piping must be repaired 

at once to prevent make-up water. Use this 

boiler ONLY in a closed-loop system.

 Con-

tinual fresh make-up water will reduce boiler life. 

Mineral buildup in heat exchangers reduces heat 

transfer, overheats the materials, and causes failure. 

Addition of oxygen carried in by make-up water can 

cause internal corrosion. 

• 

Do not add cold water to hot boiler.

 Thermal 

shock can cause heat exchanger to crack.

Freeze protection fl uids —

•  NEVER use automotive or standard glycol antifreeze. 

Use only freeze-protection fl uids made for hydronic 

systems. Follow all guidelines given by the antifreeze 

manufacturer. Thoroughly clean and fl ush any re-

placement boiler system that has used glycol before 

installing the new boiler.

Summary of Contents for 383900000

Page 1: ... the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any telephone in your building Immediately call your gas supplier from a neighbor s telephone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation service must be performed by a qualifi...

Page 2: ...substantial property damage Indicates presence of hazards that will or can causeminorpersonalinjuryorpropertydamage Indicates special instructions on installation operation or maintenance that are important but not related to personal injury or property damage To Read and use Page Locate boiler components See illustration at right 2 Learn precautions See Hazard Definitions below 2 Read before proc...

Page 3: ...t block flow of combustion or ventilation air to boiler This boiler is equipped with a control which will automatically shut down the boiler should air or vent be blocked If vent or air blockage is easily ac cessible and removable remove it The boiler should attempt to restart within an hour If blockage is not obvious or cannot be removed have the boiler and system checked by a qualified service t...

Page 4: ...ed to fasten building products and other similar products Excessive dust and dirt Areas likely to have contaminants Dry cleaning laundry areas and establishments Swimming pools Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishments New building construction Air contaminatio...

Page 5: ...uge Verify boiler jacket door is securely closed MONTHLY Check vent piping Check air piping Check relief valve Check condensate drain system Check automatic air vents if used Check display date and time EVERY 6 MONTHS Check boiler piping gas and water Operate relief valve Follow the service and maintenance procedures given throughout this manual and in component literature shipped with the boiler ...

Page 6: ...heck boiler pressure temperature gauge 1 Make sure the pressure reading on the boiler pressure temperature gauge does not exceed 24 psig if using a 30 psig relief valve typical installation Higher pressure may indicate a problem with the expansion tank 2 Contact a qualified service technician if problem persists Verify that front door is securely closed 1 Visually inspect front door to be sure it ...

Page 7: ...mitted into the boiler room through the condensate drain line or tee Follow procedure below to fill trap 3 Verify that the condensate drain line is unob structed by slowly pouring water into the top of the PVC tee on the side of the boiler The water should run out the end of the condensate drain line If the water does not run out call your qualified service technician to inspect the boiler and cle...

Page 8: ... slightly al lowing water to relieve through the valve and discharge piping 4 If water flows freely release the lever and allow the valve to seat Watch the end of the relief valve discharge pipe to ensure that the valve does not weep after the line has had time to drain If the valve weeps lift the seat again to attempt to clean the valve seat If the valve continues to weep afterwards contact your ...

Page 9: ...Part number 550 100 213 1220 9 OPERATING INSTRUCTIONS CONDENSING GAS BOILER USER S INFORMATION Manual Figure 5 Operating instructions see page 2 for location of manual gas valve ...

Page 10: ...Part number 550 100 213 1220 10 The Evergreen control display CONDENSING GAS BOILER USER S INFORMATION Manual Figure 6 EvergreenTM boiler control display states ...

Page 11: ... BOILER USER S INFORMATION Manual Resetting faults 1 During a fault the status will change to LOCKOUT and the Time Date line will alternate with the fault name The line MANUAL RESET will appear on the Boiler Status screen 2 Select MANUAL RESET to reset fault condition 3 The MANUAL RESET screen will indicate whether the fault was a manual or automatic reset the fault name and the time and date it o...

Page 12: ...Part number 550 142 123 0513 CONDENSING GAS BOILER USER S INFORMATION Manual ...

Reviews: