background image

2

 

2.1.2 Making a NEMA-4 Mounting 

Panel  
Details

 

The unit can be mounted into panels with a depth of 4”(105mm).    It is recommended that 
the unit be mounted on the front panel of a steel enclosure, through an appropriate 
opening*. Allow a clearance of 1”(25mm) around the sides of the unit for mounting 
hardware. Allow clearance for cable connections to the back of the unit. Unit depth may 
vary according to cable type used. Typically, plan a depth to accommodate at least 
4”(105mm) behind the panel. 

NEMA-4 
Mounting

 

Put the unit through the panel cut out. Slide the clamps into the 6 holes provided around 
the case. Tighten the clamping screws in an even pattern until the unit is secured in the 
panel. 

Caution!

 

Do not over tighten mounting clamps! 

Note:

 

Specifications 

Note: To seal to NEMA-4 specifications, all supplied mounting clamps must be used and 
panel cannot flex more than 0.010”. 

2.1.3 Environmental Considerations 

 

z

 

The MT-600/8000 are to be used indoors as built in displays. Make sure that the displays 
are installed correctly and that the operating limits are followed (See Specifications). 

z

 

Do not operate the unit in areas subject to explosion hazards due to flammable gases, 
vapors or dusts. 

z

 

The unit should not be installed where fast temperature variations and/or high humidity 
are present. This will cause condensation of water in the device. 

z

 

Do not install these terminals in environments where have inflammable gases. 

 

2.2 Power Connections 

Make sure that all local and national electrical standards are met when the installing the unit. 
Contact your local authorities to determine which codes apply. 

2.2.1 Power Requirements 

 

Power

 

The MT-610X/8104X can be powered by DC power only. The specified 
voltage range is 24

±

20% Volts DC.    This insures compatibility with most 

controller DC systems.   

The power conditioning circuitry inside the unit is accomplished by a 
switching power supply. The peak starting current can be as high as 2A. 

 

Fusing 
Requirements

 

If the display does not come on within 2 seconds of power up, remove 
power. An internal fuse will prevent damage if the polarity of the DC power 
is incorrect. Check wiring to insure proper connections and try to power up 
again. 

 

Caution 
High Voltage

 

An Internal fuse will prevent damage for over voltage condition however it 
isn’t guaranteed. 

DC voltage sources should provide proper isolation from main AC power 
and similar hazards. 

 

Caution 
Emergency 
Stop

 

A Hard-wired EMERGENCY STOP should be fitted in any system using an 
MT-600/8000 to comply with ICS Safety Recommendations. 

 

Caution 
Supply Voltage 
Condition 

Do not power the MT-600/8000 and inductive DC loads, or input circuitry to 
the controller, with the same power supply. Note: The 24 VDC output from 
some controllers may not have enough current to power the MT-600/8000. 

 

Summary of Contents for MT-610 Series

Page 1: ...0 Series has been tested to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Proper wire routing and grounding will insure proper operation Mechanical Environment Avoid installing units in environments where severe mechanical vibration or shocks are present 2 0 Installation...

Page 2: ...ent This will cause condensation of water in the device z Do not install these terminals in environments where have inflammable gases 2 2 Power Connections Make sure that all local and national electrical standards are met when the installing the unit Contact your local authorities to determine which codes apply 2 2 1 Power Requirements Power The MT 610X 8104X can be powered by DC power only The s...

Page 3: ...ected to a tree from a central star earth ground point This ensures that no ground conductor carries current from any other branch 2 2 3 CE Requirements To make an MT 600 8000 comply with EMC directives and to reduce susceptibility to electrical interference a separate 14 AWG ground wire should be taken to the chassis ground terminal of the power connector This ground connection should be run dire...

Page 4: ... authorized personnel can make such changes These recommendations are intended as safeguards against the failure of critical components and the effects of such failures or the inadvertent errors that might be introduced if programs are changed while the equipment is in operation z The ICS 3 304 81 Safety Recommendations are reproduced by permission of the National Electrical Manufacturers Associat...

Page 5: ...n assignment of the 9 Pin Male SUB D COM1 RS 232 and COM2 RS 232 Port Pin Designations COM1 RS 232 COM2 RS 232 Pin Symbol COM1 RS232 COM2 RS232 1 Not used 2 RxD Received Data 3 TxD Transmitted Data 4 TxD Transmitted Data 5 GND Signal Ground 6 RxD Received Data 7 RTS Ready to send output 8 CTS Clear to send input 9 Not used 2 4 2 Connector COM1 RS485 COM3 RS485 and COM3 RS232 The 9 Pin Female SUB D...

Page 6: ...r Wire MT8 Ethernet RZC045120 Direct connect Ethernet crossover cable MT8000 Ethernet RJ45 Wire color PC or Note Book RJ45 1 TX White Orange 3 RX 2 TX Orange 6 RX 3 RX White Green 1 TX 6 RX Green 2 TX MT8 COM1 RZC002320 1 5 6 9 5 9 1 6 6 9 1 5 MT8 COM3 RZC004850 5 9 1 6 1 5 6 9 1 5 6 9 5 9 1 6 ...

Page 7: ...cd m 2 Color 65 536 colors Contrast Ratio 300 1 Resolution WxH dots 640 x 480 Back light CCFLx2 CCFL life time 40 000 hr min Touch panel 4 wires resistive type Touch Accuracy 2mm Surface Hardness 4H I O port COM1 RS 232 RS 485 2W 4W COM2 RS232 COM3 RS 232 RS 4852W 1 Ethernet port 10 100 Base T SD CARD SLOT PS 2 Port Connector USB Host 2 USB Host port Audio 1 x Audio Line Out 1 x MIC In Processor A...

Page 8: ...28 43mm 1 69 COM1 RS232 COM2 RS232 COM3 RS485 COM3 RS232 COM1 RS485 2 4W SD PS 2 b a e f l m k j i h g g g g c d 50mm 1 97 A N A H SD CARD SLOT B IDE Interface DOM Slot I Com1 RS232 Com2 RS232 C Line Out J Com1 RS485 Com3 RS485 Com3 RS232 D Mic In K Ethernet Port 10 100 Base T E Fuse Reset Button L USB Host Port x 2 F Power Connector M PS 2 Port Connector G VESA 75mm Screw Holes Cutout Dimensions ...

Reviews: