The individual KNX device address and the individual KNX ad-
dresses for additional tunneling connections can be changed 
within the ETS project (ETS 4.2 and ETS 5), after the device has 
been added to the project. 

 

ETS database 

The ETS database (for ETS 4.2 and ETS 5) can be downloaded 
from the product website of the KNX IP LineMaster 762 
(www.weinzierl.de).

 

When using the ETS® product database for ETS 4 / 5 some set-
tings are displayed in addition to the parameter dialog of the 
Properties dialog (on the right side of the ETS window). So the 
IP settings can be changed here. In the ETS 4 also the addi-
tional individual addresses can be set here. In the ETS 5 those 
addresses appear in the topology view. 

 

Each individual KNX address can be changed by clicking on the 
list entry and typing in the desired address into the “Individual 
Address” text field. If the text field frame switches to color red af-
ter entering the address, the address is already taken within your 
ETS project. 

Make sure that none of the addresses above are already 
used in your KNX installation. 

By clicking on the KNX IP LineMaster 762 device entry within 
your ETS projects topology view, an information column ‘Proper-
ties’ will appear on the right side of the ETS window. Within the 
‘Settings’ overview, you can change the name of the device. 

 

Within the “IP” overview the IP network specific options of the 
KNX IP LineMaster can be changed. 

 By changing "obtain an IP address automatically (via DHCP)" to 
“Use a static IP address" (static IP address) the IP address, sub-
net mask, and default gateway can be set freely. 

All changes in the properties menu become effective 
only after a successful application download. 

 

 

 

IP address 

Here the IP address of the KNX IP LineMaster 762 can be en-
tered. This is used to address the device via the IP network 
(LAN). The IP addressing should be coordinated with the admin-
istrator of the network. 

Subnet mask 

Enter the subnet mask here. The device uses the values entered 
in this mask to determine whether there is a communication part-
ner in the local network. If there is no partner in the local net-
work, the device will not send the telegrams directly to the part-
ner but to the gateway that routes the telegram. If the device 
should not be connected to external networks (e.g. internet), the 
subnet mask shall be set to 0.0.0.0. 

Default gateway

 

Enter the IP address of the gateway here, e.g. the DSL router of 
the installation. If the device should not be connected to external 
networks (e.g. internet), this address shall be 0.0.0.0. 

Routing Multicast Address 

This address is used for routing telegrams on IP. The multicast 
IP address 224.0.23.12 was reserved (KNXnet/IP) at the IANA 
(Internet Assigned Numbers Authority) for this purpose. If a dif-
ferent multicast IP address is required, it must be within the 
range of 239.0.0.0 to 239.255.255.255. 

 

 

 

Summary of Contents for KNX IP LineMaster 762

Page 1: ...coupl IP coupling of lines IP line coupler Area Backbone TP IP IP Coupling KNX Line Coupler max 15 Pcs KNX IP Router max 15 Pcs Directly via LAN Switch Main line TP TP IP Coupling KNX Line Coupler max 15x15 Pcs KNX Line Coupler max 15x15 Pcs KNX IP Router max 225 Pcs Line TP TP TP KNX IP LineMaster 762 as line coupler The individual address assigned to the KNX IP LineMaster 762 determines whether ...

Page 2: ...t of auxiliary and Bus power o The device is not loaded correctly for example a cancelled download Factory default settings The following configuration is set by factory default Individual device address 15 15 0 Number of configured KNXnet IP tunneling con 6 Individual address of tunneling con 1 15 15 240 Individual address of tunneling con 2 15 15 241 Individual address of tunneling con 3 15 15 2...

Page 3: ...owledge only when forwarding ACK acknowledge al ways NACK negative acknowledgment When answering with NACK access to the device via KNX TP is no longer pos sible see ETS parameter settings These settings are temporary Settings differing from parameterization are marked with an angular bracket The parameterized setting can be restored with a long press on Enter H Tel Counter This submenu contains t...

Page 4: ...ase section for more information As factory default the assignment of the IP address is set to au tomatically via DHCP no further IP settings are necessary To use this feature a DHCP server on the LAN must be present e g many DSL routers have an integrated DHCP server After connecting the KNX IP LineMaster 762 to the LAN it should automatically appear in the ETS within the menu Bus under Discovere...

Page 5: ...of the device Within the IP overview the IP network specific options of the KNX IP LineMaster can be changed By changing obtain an IP address automatically via DHCP to Use a static IP address static IP address the IP address sub net mask and default gateway can be set freely All changes in the properties menu become effective only after a successful application download IP address Here the IP addr...

Page 6: ...eration on device bypass filtering The duration of the manual operating mode is set here The filter table can be bypassed temporarily for commissioning or test pur poses This can be set under the menu item Filter After termi nation the normal operating mode as programmed by ETS is au tomatically processed again Routing KNX TP IP Group telegrams main group 0 to 13 Main group 0 to 13 is the standard...

Page 7: ...vidually addressed telegrams Block No individually addressed telegrams are routed to KNX TP Route All individually addressed telegrams are routed to KNX TP Filter The individual address is used to check whether the received individually addressed telegram should be routed to KNX TP Broadcast telegrams Block No received broadcast telegrams are routed to KNX TP Route All received broadcast telegrams...

Page 8: ...se direct IP connection if available in the ETS menu Bus Connections Options The download is then directly performed in the device and is not visi ble in the ETS group monitor Due to the significantly shorter transmission times it is recommended to perform downloads via IP Weinzierl Engineering GmbH D 84508 Burgkirchen Alz Germany http www weinzierl de info weinzierl de WARNING The device must be ...

Reviews: