The Weir Group PLC
Weir Industrial Gateway setup guide rev 0.5
Copyright © Weir Minerals Australia Ltd 2017. Commercial in Confidence. All rights reserved.
Page
9
of
46
76
MPM
– Main Processing Module
The primary functions of the MPM are:
-
Run the Node Engine application(s) required for each piece of equipment
o
Convert signals captured by the RSP or other devices into TAG Metrics
o
Perform secure authentication with the Synertrex Enterprise
o
Provide remote access mechanism to allow diagnosis and analysis of issues
on site
The MPM is housed in a rugged enclosure fitted with signal conditioning, data acquisition,
data processing and cloud interfacing systems.
7.16.1
Parameters relevant to installation and operation
o
Supply : 14.6A@24Vdc
o
IP rating : 66
o
IK rating : 09
o
Hazloc : Certified for Class 1 Div 2 environment
o
Temperature range (operating) : -30°C
≤ Tamb ≤ 70°C
o
Mass : 16.7 kg / 36.8 lb
o
Casing material : Powder coating over allodyned aluminium
o
Mounting orientation: On vertical plate/wall with all connectors facing down
7.26.2
Images
Figure 6-1 MPM perspective view (cables and protective shroud removed)