Document P/N:
2A44778_SVC_MNL
Release Date:
07/29/2019
Revision: 1.0
11 of 23
2.5.4 Warnings
The red text beneath the Pop-Off Active indicator is the list of current warnings for this valve. Warnings
include improper configuration of the system (e.g. disconnected sensors or low bottle pressure).
2.6 Logging
Log files are listed on the
Log Files
tab in the web interface.
2.6.1 Logging File Format
The system records data in the Technical Data Management Streaming (TDMS) file format. The binary TDMS file format is an easily
exchangeable, inherently structured, high-speed-streaming-capable file format. Each individual log is created each time the system is
rebooted, or every 12-hours at noon (1200) and midnight (2400). Each file contains individual tabs that record 30 seconds before and
after each pop-off event that occurs as shown below.
You can view the TDMS log files in Excel by downloading the Excel TDMS Add-in available to download from National Instruments.
POP OFF EVENTS
‐
Each Pop Off Event is
recorded within each log
file as individual tabs.