Installation and operating instruction
Oil burner WL5-PB-H purflam®
4 Installation
83242002 1/2019-03 La
18-76
4 Installation
4.1 Installation conditions
Burner type and capacity graph
Burner and heat exchanger must be matched.
Check burner type and burner capacity.
Installation location
Prior to installation ensure that:
sufficient space is available for normal and service position [ch. 3.4.7],
sufficient combustion air is available, if necessary install ducted air intake,
Prepare heat exchanger
The refractory
3
must not protrude beyond the recirculation aperture
5
. It can,
however, take a conical shape (min 60°).
The distance from flame tube front edge to the rear wall of the combustion chamber
must be a minimum of 100 … 150 mm to ensure sufficient flame burn-out.
If necessary, undo locknut
2
on the sliding flange to adjust the installation depth of
Following installation, the aperture
4
between adapter pipe
1
and refractory
should be filled with flame-proof, resilient material. Do not make solid.
60°
110 mm
M8
45°
130 ... 150
0 ... 90 mm
11
0 mm
4
5
3
2
1
1
Adapter pipe
2
Locknut on sliding flange
3
Refractory
4
Aperture
5
Recirculation aperture