Installation and operating instruction
Oil burner WL5-PB-H purflam®
9 Servicing
83242002 1/2019-03 La
44-76
9.10 Set mixing head
Observe notes on servicing [ch. 9.1].
Set nozzle distance
Place burner into service position B [ch. 9.3].
Insert setting gauge and check dimension A (2.5 mm).
If the value measured deviates from dimension A:
Undo screw
1
on the guide tube and screw
2
on the mixing head.
Adjust nozzle body until dimension A is reached and ensure that the mixing head
is flush with the guide tube.
Tighten screw
1
and screw
2
.
A = 2.5 mm
1
2