6.5.44 SOL Yield DHW
This parameter is used to stipulate, if and how the DHW module reacts to the status
messages
Excess
and
Excess temp.
from the WCM-SOL.
▶
Activate heating engineer level (see Ch. 6.5).
▶
Press function key
DHW
.
✓
Menu
DHW
is displayed.
▶
Use dial knob to move to the fourth menu level.
▶
Press function key
Sol Yield DHW
.
✓
Menu
Sol Yield DHW
is displayed.
04
DHW
End
-
+
SOL yield DHW
SOL yield DHW
611
End
OK
with excess temp.
with excess
▶
Use function keys
with excess
and
with excess temp.
to stipulate, to
which status message(s) the DHW load circuit should react.
▶
Use the dial know to set the reaction of DHW loading to the status messages
(
Off
,
Normal DHW setpoint
,
maximum DHW
).
▶
Confirm with function key
OK
.
✓
The settings are applied.
Status messages
with excess
Is generated by the WCM-SOL 1.0, when a freely selecta-
ble temperature level (
P881
in the WCM-SOL 1.0) in the
buffer is exceeded due to solar input.
with excess
temp.
Diagram 1
: Is generated by the WCM-SOL 1.0, when the
temperature in the DHW tank approaches the maximum
design temperature
Diagram 2
: Is generated by the WCM-SOL 1.0, when the
temperature in the DHW tank approaches the maximum
design temperature
Reaction of the DHW load circuit
Off
The DHW load circuit does not react to the status messag-
es.
Normal DHW set-
point
The DHW load circuit reacts by heating up to the normal
level for DHW.
DHW maximum
The DHW load circuit reacts by heating up to
DHW max-
imum
.
Installation and operating instruction
Remote control station WCM-FS 2.0 and extension module WCM-EM 2.1
6 Operation
83277502 • 3/2012-10 • La
92-106
Summary of Contents for WCM-EM 2.1
Page 107: ...83277502 3 2012 10 La ...