8 Maintenance and service
8.14 Replacing the combustion manager
Observe the notes on maintenance and servicing (see Ch. 8.1).
u
Unplug all the plugs.
u
Loosen screws
1
.
u
Push and slide up the combustion manager, out from the mounting bracket.
u
Install the new combustion manager in reverse order.
u
Re-connect all the plugs to the combustion manager.
Presetting the combustion manager
u
Unplug the bridging plug No. 7 from the combustion manager.
u
Switch on the power supply.
a
The unprogrammed condition of the combustion manager is indicated by a flashing
display.
a
The burner goes to lockout.
u
Press [Enter].
a
Burner has been reset.
a
The combustion manager goes to stand-by.
u
Press [G] and [L/A] simultaneously.
a
The combustion manager goes to access level.
1