Assembly and installation instructions
Circulation station WHI circuload 9 #1; Circulation station WHI circuload 9 #2
7 Commissioning
83288702
▪
1/2014-02
▪
Ext. PAW
16-24
5.3
Controller connection
WARNING
Risk to life and limb due to electric shock!
Prior to performing electrical work on the controller,
de-energise the system.
For more information, see enclosed installation and
operation instructions of the station controller.
Connect the circulation station to the power supply
system (230 V, 50 Hz) only after completing all
installation work, filling and flushing.
This avoids an unintentional start of the motors.
The circulation station is pre-wired in the factory.
5.4
Electrical connection of the solar controller WRSol2.1
Terminal
Acronym
Description
Execution
L/N
230V
Mains connection 230 V
on site
1/N
PZWP
Primary circuit pump
prewired
2/N
PZW
Secondary circuit pump
prewired
11/┴
TZW
Secondary circuit return sensor
prewired
12/┴
TZWA
Secondary circuit flow sensor
prewired
16/┴ *
TO1
Heat source temperature
on site
17/┴
PWM2
PWM control signal for secondary pump
prewired
18/┴
PWM1
PWM control signal for primary pump
prewired
19/┴
TPR
Primary circuit return sensor
prewired
20/┴ **
TPV
Primary circuit flow sensor
prewired
21/25/┴ **
V1
Volume pulse input collector loop
prewired
*
required when using the WHI circuload in combination with a pre-heat buffer
(hydraulic version 39).
** only with WHI
circuload 9 #2
6
Operation
A detailed description of the operation of the controller can be found in the enclosed
controller manual.
Solar controller WRSol 2.1 pre-settings
•
Hydraulic version 39
•
eBUS address 3
•
Heat flow meter option (with WHI circuload 9 #2)
•
Pulse rate 55 pulses/litre (with WHI circuload 9 #2)