3 Product description
83288702
▪
1/2014-02
▪
Ext. PAW
8-24
3.1
Function
The WHI circuload 9 circulation stations are used in domestic water networks in order to
cover the loss of heat of the circulation line from a heat storage device using a
heat exchanger.
WHI circuload modules are integrated into the domestic water system parallel to the
WHI freshaqua or WHI load modules. The direct supply of the modules with hot water
from the buffer tank guarantees an energy and cost-optimised operation of the circulation
system.
The return line of the circuload modules can be integrated into the buffer tank / tanks
independent of the return line of the WHI freshaqua or WHI load modules. A mixture of
hot and cold water is therefore reduced to a minimum so that the degree of utilisation of
the entire system improves compared with systems without separate circulation module.
The WHI circuload 9 #2 module is also equipped with a heat flow meter in the heating
circuit in order to allow for a simple balancing of the energy required.