4.2 Selecting a nozzle
Determine nozzle size.
Recommended nozzles
Make
Characteristics
Steinen
(1
60°S, 60°H
Fluidics
45°SF
(2
, 45°HF
(1
We recommend Fluidics nozzles for nozzle sizes 1.00 gph and 1.10 gph.
(2
Only from 12 bar pump pressure and single pipe system (higher oil temperat-
ures).
Pump pressure setting
10 …
12
… 14 bar
Spray characteristic and spray angle varies depending on pump pressure.
Nozzle selection table
Different load values are possible due to tolerances.
Burner capacity [kW] at pump pressure
Nozzle size [gph]
10 bar
11 bar
12 bar
13 bar
14 bar
1.00
–
–
49.5
51.2
53.6
1.10
49.5
52.4
54.7
57.1
58.3
1.25
55.9
59.5
61.9
64.3
66.6
1.35
60.7
64.3
66.6
69.0
72.6
1.50
67.8
71.4
73.8
77.4
79.7
1.65
75.0
78.5
82.1
85.7
88.1
1.75
78.5
83.3
86.9
90.4
94.0
2.00
90.4
95.2
98.8
102.3
107.1
Conversion of burner capacity to oil throughput see formula below.
Oil throughput in kg/h =
Burner capacity in kW
11.9 kWh/kg