Installation and operating instruction
Oil burner WL40/1-A Z-1LN-A
6 Operation
83319702 1/2020-10 La
31-116
Operating status
The exact operating status of the combustion manager can also be displayed. This
simplifies determining the cause of a fault during troubleshooting [ch. 11.1].
Press and hold [–] and [+] simultaneously for approx. 3 seconds.
The combustion manager changes to operating display. The display shows cur-
rent operating status with a number.
Back to standard display:
Press and hold [–] and [+] simultaneously for approx. 3 seconds.
VisionBox Software (optional)
If the VisionBox Software is connected, change-over to the access level must be
confirmed via the operating panel.
Press [+]
Software changes to the access level
Flame sensor LFS1 (optional)
Only in conjunction with continuous operation.
Illuminated push button
Operating condition
yellow
Standby
Green
Flame signal OK
Flashing green
Flame signal too weak (< 10 μA) [ch. 10.3]
red