6.2.1 Info level
Burner data can be interrogated in the Info level .
Press [Enter] for approx. 0.5 seconds.
The Info level is activated.
Press [Enter] to reach the next information.
l,m³
No.
Information
0
Total oil consumption in litres (via X3:8)
Reset value:
Press [L/A] and [+] simultaneously for approx. 2 seconds.
1
Hours run stage 1
2
Hours run stage 2
3
Burner starts
4
Device item number
5
Index of device item number
6
Device number
7
Production date (DDMMYY)
8
Fieldbus address
10
Oil pressure switch function
11
Current fan speed (only in conjunction with variable speed drive)
Display of standardised speed:
Press key [L/A].
12
Current oil consumption (0.1 l/h)
13
Analogue module EM3/3 or Fieldbus module EM3/2 available
0
: no
1
: yes