Installation and operating instruction
Oil burner WL5/1-B
9 Servicing
83272002 1/2019-04 La
40-76
9.7 Set mixing head
Observe notes on servicing [ch. 9.1].
Set nozzle distance
Place burner into service position A [ch. 9.3].
Insert checking gauge and check dimension A (3 mm).
If the value measured deviates from dimension A:
Undo screw
1
.
Adjust nozzle body
2
until dimension A is reached.
Re-tighten screw
1
.
A = 3 mm
1
2